Comparative Study on Characteristics of Partial Discharge Optical Pulse and UHF Pulse in Switch Equipment

نویسندگان

چکیده

Abstract The article explores the performance of new silicon photoelectric sensor in partial discharge detection, and compares measured optical pulse with traditional UHF pulse. Through electrical synchronous experiments, analyzes discusses detection performance, working characteristics statistical various sensors, advantages feasibility sensors actual monitoring; In addition, two physical phenomena light radiation electromagnetic was obtained through analysis monitoring data. Compared sensor, under optimal voltage has a higher signal-to-noise ratio (SNR); Under interference high-frequency motor, exhibits better anti-electromagnetic ability; Discharge phase interval reflected by PRPD methods maintain good consistency; Pulse repetition rate same trend applied voltage, but frequency pulses is than that because SNR single-photon sensitivity.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Study on Miniaturized UHF Antennas for Partial Discharge Detection in High-Voltage Electrical Equipment

Detecting partial discharge (PD) is an effective way to evaluate the condition of high-voltage electrical equipment insulation. The UHF detection method has attracted attention due to its high sensitivity, strong interference resistance, and ability to locate PDs. In this paper, a miniaturized equiangular spiral antenna (ESA) for UHF detection that uses a printed circuit board is proposed. I-sh...

متن کامل

Study on time-frequency extractors for partial discharge pulse current used in sequence grouping and identification

This paper introduces a general way to make feature extraction for partial discharge (PD) pulse waveshape used in sequence grouping resorting with equivalent time-frequency method. A digital ac PD pulse detection system with bandwidth of 10 kHz 40 MHz and sampling rate of 100 MS/s is introduced, which was developed to study those feature extractors. Simulation and test results with gas insulate...

متن کامل

a comparative study of the relationship between self-, peer-, and teacher-assessments in productive skills

تمایل به ارزیابی جایگزین و تعویض آن با آزمون سنتی مداد و کاغذ در سالهای اخیر افزایش یافته است. اکثر زبان آموزان در کلاس های زبان از نمره نهایی که استاد تعیین میکند ناراضی اند. این تحقیق جهت بررسی ارزیابی در کلاس های زبان انگلیسی به هدف رضایتمندی زبان آموزان از نمره هایشان انجام گرفته است که در آن نمرات ارائه شده توسط سه گروه ارزیاب (ارزیابی خود دانشجو، همسالان واستاد) در مهارت های تولید (تکل...

15 صفحه اول

Study on Monitoring System for Partial Discharge of Electrical Equipment

The detection and fault identification of the partial discharge is the important aspect for the monitoring of the power equipment. For the lacks of the traditional detection methods, this paper analyzed the UHF signal characteristic parameters of the power equipment’s partial discharge, and developed the UHF detection system of the partial discharge. The A/D technology of the gain equalization ...

متن کامل

Uhf Monitoring of Partial Discharge in Substation Equipment Using a Novel Multi-sensor Cable Loop

This paper describes the development of a partial discharge measurement system that utilises a multiplexed approach to ultra-high-frequency monitoring on many pieces of equipment using a single cable loop connected to only two sampling channels. It is envisioned that the system could be used in partial discharge monitoring of medium voltage metal-enclosed switchgear, or several power transforme...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of physics

سال: 2021

ISSN: ['0022-3700', '1747-3721', '0368-3508', '1747-3713']

DOI: https://doi.org/10.1088/1742-6596/2136/1/012024