Comparison of IOL--master and ultrasound biometry in preoperative intra ocular lens (IOL) power calculation.

Postoperative refractive outcome largely depends on the accuracy of calculating power of implanted IOL. Lens power calculation can be done by conventional ultrasound biometry and partial coherence laser interferometry (IOL Master). The aim was to compare the accuracy of IOL power calculations using conventional ultrasound biometry and partial coherence laser interferometry.40 eyes were included...

متن کامل

Ocular Axial Length Measurement Using Regular Ultrasound and IOL Master for Different Refractive Errors in Egyptian Population

Background and Objective: The main purpose of this paper is to compare the reliability and repeatability of data obtained clinically with the IOL Master with those using a standard applanation ultrasound biometry on different refractive error types to measure axial length. Patients and Methods: 39 patients were examined by both the IOL Master and the Sonomed for axial length measurement and IOL...

متن کامل

Optimizing Cataract and Refractive Outcomes: Maximizing IOL Technology

T hese refractive IOLs offer many advantages: They are more stable than any surface procedure, provide better visual optics than surface procedures, and offer the real ability to correct presbyopia. But they also have serious downsides: Patients often complain of glare, halo, and loss of contrast sensitivity. I consider them a high-wire act—when things go smoothly, they are great, but everythin...

متن کامل

مقایسه‌ی کراتومتری پنتاکم وکراتومتری IOL Master در محاسبه‌ی لنز داخل چشمی افراد با قرنیه‌ی طبیعی

Background and Objective: Proper method and machine for corneal evaluation is an important factor in many anterior segment interventions. This study was performed to compare the mean keratometry (K) readings obtained with an IOL Master and Pentacam for intraocular lens power calculation in normal subjects with no history of refractive surgery. Materials and Methods: Mean K values were obtained ...

متن کامل

Comparison of the biometric measurements calculated with Zeiss IOL-Master and WaveLight OB-820

BACKGROUND The primary objective of this study was to investigate the level of agreement between IOL-Master and OB-820 ocular biometers. MATERIALS AND METHODS In this prospective randomized case series, we measured the anterior chamber depth (ACD), the axial length (AL), the corneal radii (R1, R2), the ratio of mean corneal radius and spherical equivalent and the corneal astigmatism (cylinder...