Compliance verification method on CCAR 25.1443(c) for civil aircraft passenger oxygen system based on blood oxygen saturation
نویسندگان
چکیده
Abstract This paper generally introduces the compliance verification method on airworthiness regulation CCAR 25.1443(c) of popular passenger oxygen system civil aircraft firstly, then technical interpretation <Minimum Mass Flow Supplemental Oxygen> is demonstrated and satisfying this in Top-Down design analyzed. For those based blood saturation which not directly fulfill requirement regulation, equivalent altitude theory established to transform mean tracheal partial pressure required by index altitude, user’s these or higher than that transformed from through actual human body physiological test theoretical analysis aviation physiology, Equivalent Level Safety. gives for have been used gotten approval Authority a type aircraft. also provides basis further revising CCAR25.1443(c).
منابع مشابه
A Microcolorimetric Method for Measuring the Oxygen Saturation of Blood
For purposes of measuring oxygen saturation in the arterial blood of newly born infants (1) it became necessary to develop a rapid and reasonably accurate method for small blood samples. It was further necessary to demonstrate that cutaneous blood samples could be considered identical with specimens drawn directly from an artery. The present communication describes the calorimetric method evolv...
متن کاملMapping Blood Oxygen Saturation using a Multi-Spectral Imaging System
Recent advances in imaging spectroscopy provide the opportunity for mapping the oxygen saturation of blood in skin with high accuracy, large spatial coverage, small spatial resolution, and high update rate. A four—wavelength algorithm, specifically designed to compute the oxygen saturation of hemoglobin, in vivo, from a set of narrow-band visible images was used to analyze various skin tissue d...
متن کاملComparing the Effect of Simple Filtration Hemodialysis and Ultrafiltration Hemodialysis on Arterial Oxygen Saturation and Blood Pressure in Chronic Dialysis
Background and purpose: Hypoxemia and hypotension are important complications of hemodialysis in patients with chronic renal failure that are linked to several factors, including the type of filters used. The aim of this study was to compare the effect of simple filtration hemodialysis and ultrafiltration hemodialysis on blood pressure and blood arterial oxygen level. Materials and methods: In...
متن کاملMisunderstanding the arterial blood oxygen saturation
Case report An 88-year-old woman was admitted to the emergency department of our hospital with an itchy skin rash that developed while she was on antibiotics (quinolones), administered for an episode of acute cystitis, asthenia and fever. She was suspected to have an allergic reaction and treated with i.v. methylprednisolone 40 mg per day. After 24 hours, skin rash and fever had subsided and th...
متن کاملA Bioreactor System Based on a Novel Oxygen Transfer Method
JUNE 2008 B ioreactor technologies for mammalian cell culture may seem quite sophisticated (1). In fact, efficient mammalian cell culture is simple and requires just two major elements: mixing and oxygen (O2) transfer. Traditional methods for mixing use an impellor, and the classical O2 transfer method features a sparging stone that expels air bubbles to increase the O2 transfer surface area in...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of physics
سال: 2023
ISSN: ['0022-3700', '1747-3721', '0368-3508', '1747-3713']
DOI: https://doi.org/10.1088/1742-6596/2551/1/012004