Computer‐assisted beam modeling for particle therapy
نویسندگان
چکیده
منابع مشابه
Status of Electron Beam Ion Sources for Particle Therapy∗
The technical performance of ion sources of the Electron Beam Ion Source (EBIS) type has substantially improved during the last years. This is demonstrated by proof-ofprinciple experiments which have been done using a roomtemperature EBIS, a so-called Dresden EBIS-A, which has been in use for several years. A new superconducting EBIS, a so-called Dresden EBIS-SC, has been taken into operation. ...
متن کاملBeam Monitors of Nirs Fast Scanning System for Particle Therapy
At National Institute of Radiological Sciences (NIRS), more than 6500 patients have been successfully treated by carbon-ion beams since 1994. The successful results of treatments have led us to construct a new treatment facility equipped with three-dimensional pencil beam scanning irradiation system. The commissioning of NIRS fast scanning system installed into the new facility was started in S...
متن کاملMonte Carlo modeling in CT-based geometries: dosimetry for biological modeling experiments with particle beam radiation
The space radiation environment imposes increased dangers of exposure to ionizing radiation, particularly during a solar particle event (SPE). These events consist primarily of low energy protons that produce a highly inhomogeneous dose distribution. Due to this inherent dose heterogeneity, experiments designed to investigate the radiobiological effects of SPE radiation present difficulties in ...
متن کاملA Simple Method for Modeling Open Cracked Beam
Abstract A simple method is proposed to model the open cracked beam structures. In this method, crack is modeled as a beam element. Hence cracked beam can be assumed to be a beam with stepped cross sections, and problem of determining natural frequency and mode shape of cracked beam, can be solved as determining these characteristics for a beam with different length and cross section. With this...
متن کاملMathematical Modeling for Thermoelastic Double Porous Micro-Beam Resonators
In the present work, the mathematical model of a homogeneous, isotropic thermoelastic double porous micro-beam, based on the Euler-Bernoulli theory is developed in the context of Lord-Shulman [1] theory of thermoelasticity. Laplace transform technique has been used to obtain the expressions for lateral deflection, axial stress, axial displacement, volume fraction field and temperature distribut...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Medical Physics
سال: 2020
ISSN: 0094-2405,2473-4209
DOI: 10.1002/mp.14647