Continuous Monitoring of Hepatic Venous Oxyhemoglobin Saturation During Cardiopulmonary Bypass.
نویسندگان
چکیده
منابع مشابه
During Hypothermic Cardiopulmonary Bypass-Correlation with Oxyhemoglobin Saturation
In 8 adult patients undergoing cardiopulmonary bypass, the perfusion flow was altered from 2.4 to 1.8 and 1.2 L/min/m during hypothermia (26.5 ± 2.3°C). Following rewarming of the patients to 37°C, the perfusion flow was also altered from 2.4 to 1.8 and 1.2 L/min/m • The resulting mixed venous oxyhemoglobin saturation (Sv0 2 ) was measured in vivo by in-line oximetry at the actual body temperat...
متن کاملContinuous monitoring of mixed venous oxygen saturation during aortic surgery.
The correlation between mixed venous oxygen saturation (SvO2) and hemodynamic measurements was studied in 13 patients undergoing descending thoracic aortic aneurysm resection (DTAAR). A significant correlation (p less than 0.05) was found between cardiac index (CI) and SvO2 after the induction of anesthesia and at the end of surgery. However, no significant correlation could be found between Sv...
متن کاملContinuous intra-jugular venous blood-gas monitoring with the Paratrend 7 during hypothermic cardiopulmonary bypass.
We measured the accuracy of the continuous intra-vascular blood-gas monitoring system (Paratrend 7, PT7) placed in the jugular venous bulb in 18 adult patients having cardiac or aortic surgery with hypothermic cardiopulmonary bypass (CPB). After induction of anaesthesia, a PT7 sensor was inserted through a 20-gauge venous catheter into the right jugular venous bulb. Blood samples were drawn fro...
متن کاملHeparin monitoring during cardiopulmonary bypass.
Three procedures have been compared for monitoring heparin in patients undergoing cardiopulmonary bypass: (1) activated clotting time (ACT) (2) protamine titration, and (3) fluorometric substrate assay. The ACT monitors the degree of anticoagulation. It is easy to perform and is relatively inexpensive, however, it does not correlate well with heparin levels and may not accurately predict the pr...
متن کاملEffects of increasing FiO2 on venous saturation during cardiopulmonary bypass in the swine model.
Adequacy of perfusion during cardiopulmonary bypass (CPB) is dependent on nutrient delivery and waste removal from the tissue. A recent study showed that over 75% of cardiopulmonary bypass procedures are completed using continuous venous saturation (SvO2) monitoring. The purpose of this study was to determine the effect of changing FiO2concentration on SvO2. A total of eight mixed gender 45-kg ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: THE JOURNAL OF JAPAN SOCIETY FOR CLINICAL ANESTHESIA
سال: 1996
ISSN: 0285-4945,1349-9149
DOI: 10.2199/jjsca.16.157