Correction of Current Transformer Transient Performance
نویسندگان
چکیده
منابع مشابه
Mitigation Transformer Inrush Current Using Modified Transient Current Limiter
This study presents a modified transient current limiter (MTCL) for mitigation the inrush current of transformers. The MTCL is based on conventional transient current limiter (TCL), which, its configuration is modified to overcome the TCL drawbacks of operation. The proposed MTCL offers lower power losses and voltage/current THD during normal operation mode. It needs only one limiting reactor i...
متن کاملCurrent Transformer Performance study Using Software Tools
Power system protective relaying systems are striving to meet the demands of systems which are ever increasing in complexity. . High-speed digital relays must make decisions while the power system is still in transition. Understanding the operation and performance of microprocessor based relays requires new engineering tools. Current transformer (CT) and relay modeling are practical tools to ev...
متن کاملA New Current Transformer Model
This paper presents a current transformer model that is useful on low frequency applications. To describe the iron core magnetic behaviour of the iron core, a hysteresis model is proposed, which is able to generate minor asymmetric loops and remanent flux. The effects of classic eddy current losses and anomalous losses are represented by linear and nonlinear resistors, respectively. The obtaine...
متن کاملCorrection to: Investigation of Electrocoagulation Process Performance with DC Current in Treatment of Poultry Slaughterhouse Wastewater Using Aluminum Electrodes
Correction to: Investigation of Electrocoagulation Process Performance with DC Current in Treatment of Poultry Slaughterhouse Wastewater Using Aluminum Electrodes Zabiholllah Yousefi1, Hossein Sahebian2, Abdoliman Amouei3, Reza Ali Mohammadpour4, Ebrahim Zarei5 1 Professor, Department of Environmental Health Engineering, Faculty of Health, Mazandaran University of Medical Science...
متن کاملPower Transformer Modeling for Inrush Current Calculation
The paper documents a new transformer model in ATPDraw called XFMR. This model handles 3-phase transformers with two or three windings. Autotransformers and all Wye and Delta couplings are supported. The model includes an inverse inductance matrix for the leakage description, optional frequency dependent winding resistance, capacitive coupling, and a topologically correct core model (3and 5-leg...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Power Delivery
سال: 2008
ISSN: 0885-8977,1937-4208