Correction of eddy current distortions in high angular resolution diffusion imaging.

PURPOSE To correct distortions caused by eddy currents induced by large diffusion gradients during high angular resolution diffusion imaging without any auxiliary reference scans. MATERIALS AND METHODS Image distortion parameters were obtained by image coregistration, performed only between diffusion-weighted images with close diffusion gradient orientations. A linear model that describes dis...

متن کامل

Quantitative Simulation of Affine Registration for Correction of Eddy Current Distortions in Diffusion-Weighted Images

R. G. Nunes, I. Drobnjak, S. Clare, P. Jezzard, M. Jenkinson Centre for Functional MRI of the Brain, University of Oxford, Oxford, United Kingdom Introduction: Diffusion-weighted (DW) imaging has shown great potential for mapping white matter tracts in the brain [1]. In order to be able to infer on fibre structure, DW images need to be collected under a set of different diffusion gradient direc...

متن کامل

Diffusion Simulation Tractography for High Angular Resolution Diffusion Imaging

Introduction While the standard diffusion tensor imaging (DTI) approach has proven to be a valuable tool in detecting local tissue structure and reconstructing neural fiber networks in brain, it cannot accurately reveal the white matter structure in the presence of multiple fiber orientations within a single voxel. In particular, for crossed fibers, the second-order diffusion tensor model fails...

متن کامل

High angular resolution diffusion imaging with stimulated echoes: compensation and correction in experiment design and analysis

Stimulated echo acquisition mode (STEAM) diffusion MRI can be advantageous over pulsed-gradient spin-echo (PGSE) for diffusion times that are long compared with T2 . It therefore has potential for biomedical diffusion imaging applications at 7T and above where T2 is short. However, gradient pulses other than the diffusion gradients in the STEAM sequence contribute much greater diffusion weighti...

متن کامل

Optimal Acquisition Schemes in High Angular Resolution Diffusion Weighted Imaging

The recent challenge in diffusion imaging is to find acquisition schemes and analysis approaches that can represent non-gaussian diffusion profiles in a clinically feasible measurement time. In this work we investigate the effect of b-value and the number of gradient vector directions on Q-ball imaging and the Diffusion Orientation Transform (DOT) in a structured way using computational simulat...