Cryogenic sapphire oscillator with exceptionally high long-term frequency stability
نویسندگان
چکیده
منابع مشابه
Cryocooled sapphire oscillator with ultrahigh stability
We present design details and test results for the first short-term frequency standard to achieve ultra-high stability (oy < without he use of liquid helium. Technical features include vibration isolation by atmospheric helium gas and a new sapphire resonator design with adjustable compensation operating at 8-10K.
متن کاملUltrahigh long-term dimensional stability of a sapphire cryogenic optical resonator.
We report on the ultrahigh long-term dimensional stability of a crystalline cryogenic optical resonator (CORE) cooled to liquid-helium temperature. The frequency of a Nd:YAG laser stabilized to a CORE was compared over long times with an independent laser system, a frequency-doubled Nd:YAG laser stabilized to a hyperfine line of molecular iodine at 532 nm. Over a 6-month period the drift was le...
متن کاملFrequency Stability of 1×10 in a Compensated Sapphire Oscillator Operating above 77 K
We report on tests of a compensated sapphire oscillator (CSO) which shows frequency-stable operation at temperatures above 77 K[1]. The frequency stability for this oscillator shows an apparent flicker floor of 7.5×10 for measuring times between 3 and 10 seconds, and stability better than 2×10 for all measuring times between 1 and 100 seconds. These values are approximately the same as for the ...
متن کاملThermal lensing in cryogenic sapphire substrates
We report the reduction of the thermal lensing in cryogenic sapphire mirrors, which is planed to be used in the Large scale Cryogenic Gravitational wave Telescope (LCGT) project. We measured three key parameters of sapphire substrate for thermal lensing at cryogenic temperature. They are optical absorption coefficient, thermal conductivity and temperature coefficient of refractive index at cryo...
متن کاملTemporal stability of long-term measures of fundamental frequency
We investigated long-term mean, median and base value of F0 to estimate how long it takes their variability to stabilize. Change point analysis was used to locate stabilization points. In one experiment, stabilization points were calculated in recordings of the same text spoken in 26 languages. Average stabilization points are 5 seconds for base value and 10 seconds for mean and median. Varianc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Applied Physics Letters
سال: 2006
ISSN: 0003-6951,1077-3118
DOI: 10.1063/1.2387969