Deconvolution method to split up X-ray peaks emitted by 223Ra
نویسندگان
چکیده
منابع مشابه
X-ray deconvolution microscopy.
Recent advances in single-photon-counting detectors are enabling the development of novel approaches to reach micrometer-scale resolution in x-ray imaging. One example of such a technology are the MEDIPIX3RX-based detectors, such as the LAMBDA which can be operated with a small pixel size in combination with real-time on-chip charge-sharing correction. This characteristic results in a close to ...
متن کاملApplication of a Fast Deconvolution Method to HPIC Peaks
2 Introduction Resolution is one of the principal aims of all chromatographic techniques. Therefore, a major goal of chromatographic method development is to obtain an adequate separation of all components of interest in a reasonable time. However, in spite of ongoing instrumentation improvements, peaks are often poorly resolved and measurements must be made using deconvolution programs. In som...
متن کاملDeconvolution of ASCA X-ray data: I. Spectral-imaging method
In this paper we describe a self-contained method for performing the spectral-imaging deconvolution of X-ray data on clusters of galaxies observed by the ASCA satellite. Spatiallyresolved spectral studies of data from this satellite require such a correction because its optics redistribute photons over regions which are of comparable size to the angular scales of interest in clusters. This scat...
متن کاملX-ray Emission Spectrum of Liquid Ethanol: Origin of Split Peaks.
The X-ray emission spectrum of liquid ethanol was calculated using density functional theory and a semiclassical approximation to the Kramers-Heisenberg formula including core-hole-induced dynamics. Our spectrum agrees well with the experimental spectrum. We found that the intensity ratio between the two peaks at 526 and 527 eV assigned as 10a' and 3a″ depends not only on the hydrogen bonding n...
متن کاملClinical relative biological effectiveness of low-energy x-rays emitted by miniature x-ray devices.
Several groups are developing ultra-miniature x-ray machines for clinical use in radiation therapy. Current systems are for interstitial radiosurgery and for intravascular insertion for irradiation to prevent re-stenosis. Typical generating voltages are low, in the 20 to 40 kV range. It is well established that the biological effectiveness of such low-energy photons is large compared with highe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Brazilian Journal of Radiation Sciences
سال: 2018
ISSN: 2319-0612,2319-0612
DOI: 10.15392/bjrs.v6i1.353