Delayed Fracture of GFRP Laminates under Constant Tensile Load in Hydrochloric Acid
نویسندگان
چکیده
منابع مشابه
Performance of Corrosion-Damaged HSC Beams Strengthened with GFRP Laminates
This paper presents the results of an experimental program conducted for evaluating the performance of corrosion damaged HSC beams strengthened with GFRP laminates. Five Beam specimens of size 150x250x3000 mm were caste and tested for the present investigation. One beam specimen was neither corroded nor strengthened to serve as reference. Two beams were corroded to serve as corroded control. A ...
متن کاملSignificance of stainless steel wire reinforcement on the mechanical properties of GFRP composites
Investigations on flexural and tensile properties of GFRP laminates influenced by stainless steel wire reinforcement were carried out as a novel approach. Plain GFRP laminates and GFRP laminates reinforced with stainless steel wires at different depth with various pitch distances were fabricated by hand layup method. The composite specimens reinforced with steel wires were exposed to low freque...
متن کاملDynamic fracture of tantalum under extreme tensile stress
The understanding of fracture phenomena of a material at extremely high strain rates is a key issue for a wide variety of scientific research ranging from applied science and technological developments to fundamental science such as laser-matter interaction and geology. Despite its interest, its study relies on a fine multiscale description, in between the atomic scale and macroscopic processes...
متن کاملTheory of the physical characteristics of tensile fracture under pressure.
(1) Bridgman's Observational Results.-It was observed by Bridgman' that there is a linear relationship between the hydrostatic pressure p and the natural strain at fracture, i.e., the ductility, in tensile tests on steel cylinders, and that this relationship persists regardless of the type of fracture which occurs. A theoretical explanation of the foregoing result has been given in an earlier p...
متن کاملExperimental study of grouted sleeve lapping connector under tensile load
The performance of the grouted sleeve lapping connector that is used to connect reinforcement bars in a precast concrete structure is studied. A total of 63 specimens, varying in bar diameter and lap length, were tested under tensile load. The failure modes, ultimate tensile strength values and load-displacement curves of the specimens are discussed in the study. Two equations are proposed for ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Solid Mechanics and Materials Engineering
سال: 2011
ISSN: 1880-9871
DOI: 10.1299/jmmp.5.669