Design of direct acting differential pressure control valve test bench
نویسندگان
چکیده
This article aims to acquaint readers with a designed test bench for direct acting differential pressure control valves. These valves are used in district heating systems. The conformity of the construction international standard IEC 60534-2-3:2015 is evaluate and results an experimental study valve AVPB DN20 Kvs 6.3 PN16 present.
منابع مشابه
Performance study of a diaphragm type crankcase pressure control valve
Pressure control valve (PCV) is implemented in internal combustion engine to regulate crankcase pressure. In this study, the performance of a diaphragm PCV valve is investigated numerically and experimentally. Firstly, numerical simulation is carried out using commercial code to predict the flow and pressure distribution inside the valve. Furthermore, downstream and upstream pressure of the val...
متن کاملA Test Bench for Differential Circuits
Last updated on September 12, 2006. You can find the most recent version at www.designersguide.org. Contact the author via e-mail at [email protected]. Permission to make copies, either paper or electronic, of this work for personal or classroom use is granted without fee provided that the copies are not made or distributed for profit or commercial advantage and that the copies are comple...
متن کاملPID Control Analysis of Brake Test Bench
In this paper, the control methods of brake test bench are studied. According to as much as possible consistent principle of braking process between on the test bench and road test vehicle, by controlling motor to work under certain regular current, compensate lack energy owing to the shortage of electricity, establish control model of equivalent inertia and vehicle load. At the same time, we m...
متن کاملVirtual Test Bench for Design and Simulation of Data Converters
This work presents a simulation environment for the design of data converters using behavioral modeling and the MATLABSIMULINK platform. This environment utilizes a graphic user interface as a CAD tool to design and simulate different data converter architectures. Postprocessing analysis tools are included for static and dynamic performance calculation. Introduction A data converter system cont...
متن کاملInvestigations of Response Time Parameters of a Pneumatic 3/2 Direct Acting Solenoid Valve Under Various Working Pressure Conditions
In pneumatic circuits, a solenoid valve is a key component for controlling and directing pneumatic energy. The solenoid valve functional performances are defined as response time parameters with respect to its actuations in terms of direction changing time. This paper aims to present response time parameters of solenoid valves under various working pressures. An experimental setup is employed i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: E3S web of conferences
سال: 2021
ISSN: ['2555-0403', '2267-1242']
DOI: https://doi.org/10.1051/e3sconf/202132704002