Determination of electrostatic potentials at biological interfaces using electron-electron double resonance

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electrostatic Potentials at Solid/Liquid Interfaces*

This review deals with electrostatic potentials within solid/electrolyte interfaces. The electrostatic potentials of several planes are defined and discussed: the inner surface potential affecting the state of charged surface species due to interactions with potential determining ions (Ψ0), the potential affecting the state of associated counterions (Ψβ), the potential at the onset of diffuse l...

متن کامل

Electron Gases at Oxide Interfaces

1027 Abstract Two-dimensional electron gases (2DEGs) based on conventional semiconductors such as Si or GaAs have played a pivotal role in fundamental science and technology. The high mobilities achieved in 2DEGs enabled the discovery of the integer and fractional quantum Hall effects and are exploited in high-electron-mobility transistors. Recent work has shown that 2DEGs can also exist at oxi...

متن کامل

Coherent pump pulses in Double Electron Electron Resonance spectroscopy.

The recent introduction of shaped pulses to Double Electron Electron Resonance (DEER) spectroscopy has led to significant enhancements in sensitivity through increased excitation bandwidths and improved control over spin dynamics. The application of DEER has so far relied on the presence of an incoherent pump channel to average out most undesired coherent effects of the pump pulse(s) on the obs...

متن کامل

Molecular orientation studies by pulsed electron-electron double resonance experiments.

Pulsed electron-electron double resonance (PELDOR) has proven to be a valuable tool to measure the distribution of long range distances in noncrystalline macromolecules. These experiments commonly use nitroxide spin labels as paramagnetic markers that are covalently attached to the macromolecule at specific positions. Unless these spin labels are flexible in such a manner that they exhibit an a...

متن کامل

Pulsed electron-nuclear double resonance (ENDOR) at 140 GHz.

We describe a spectrometer for pulsed ENDOR at 140 GHz, which is based on microwave IMPATT diode amplifiers and a probe consisting of a TE011 cavity with a high-quality resonance circuit for variable radiofrequency irradiation. For pulsed EPR we obtain an absolute sensitivity of 3x10(9) spins/Gauss at 20 K. The performance of the spectrometer is demonstrated with pulsed ENDOR spectra of a stand...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Biophysical Journal

سال: 1992

ISSN: 0006-3495

DOI: 10.1016/s0006-3495(92)81950-1