Determination of Glucose Concentration in Aqueous Solution Using ATR-WT-IR Technique

Fourier transformation infrared (FT-IR) spectroscopy has been used to measure glucose concentrations in different matrices. The accuracy of the FT-IR technique does not meet the requirements of medical applications, so we have developed a new, efficient and precise method based on attenuated total reflectance coupled with wavelet transformation (ATR-WT-IR). One thousand interferograms, divided ...

متن کامل

Determination of concentration of saturated ferrocene in aqueous solution

Correspondence: Koichi Jeremiah Aoki Department of Applied Physics, University of Fukui, 3-9-1 Bunkyo, Fukui, 910-0017 Japan Tel +817 7627 8665 Fax +817 7627 8750 Email [email protected] Abstract: The solubility of ferrocene in aqueous solution is known to be approximately 0.04 mmol/dm. The solubility values determined by voltammetry have been overestimated because of adsorption on electrodes...

متن کامل

development of different optical methods for determination of glucose using cadmium telluride quantum dots and silver nanoparticles

a simple, rapid and low-cost scanner spectroscopy method for the glucose determination by utilizing glucose oxidase and cdte/tga quantum dots as chromoionophore has been described. the detection was based on the combination of the glucose enzymatic reaction and the quenching effect of h2o2 on the cdte quantum dots (qds) photoluminescence.in this study glucose was determined by utilizing glucose...

Determination of glucose in human aqueous humor using Raman spectroscopy and designed-solution calibration.

Glucose concentrations of in vitro human aqueous humor (HAH) samples from cataract patients were determined using 785 nm Raman spectra and partial least squares (PLS) calibration. PLS models were created from spectra of prepared calibration solutions rather than aqueous humor samples. Spectra were obtained with an excitation energy (100 mW for 150 s), which was higher than can be applied in viv...

متن کامل

Degradation of High-Concentration of Perchloroethylene from Aqueous Solution Using Electro-Fenton Process

Introduction: Perchloroethylene (PCE) is one of the most well-known chlorinated organic compounds recently detected in aqueous environments. The presence of PCE in aquatic ecosystems has caused many health problems and environmental challenges. Therefore, its removal and treatment from aqueous environments are essential. Materials and Methods: The electro-Fenton (EF) process was carried out in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Sensors

سال: 2009

ISSN: 1424-8220

DOI: 10.3390/s90806254