Determination of platinum-group elements in rocks by ICP-MS with external calibration after cation exchange separation of matrix elements by KU-2-8 resin

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Actinide Elements in Environmental Samples by Icp-ms

DETERMINATION OF ACTINDE ELEMENTS iN ENVIRONMENTAL SAMPLES BY ICP-MS Jason Bedford Truscott Methods for the determination of the actinide elements m water, biological, soil and sediment samples have been developed usmg on-line sohd phase extraction and high performance liquid chromatography (I{PLC) coupled with mductively coupled plasma mass spectrometry (ICP-MS) Initial applications utilised a...

متن کامل

Accurate Measurement of Rare Earth Elements by ICP-MS after Ion-Exchange Separation: Application to Ultra-Depleted Samples

This study reports precise and accurate data for rare earth elements (REE) measured on eight geological reference materials, five enriched in REE (BE-N, BHVO-2, BR, BR-24 and RGM-1) and three very depleted in REE (BIR-1, UB-N and DTS-2). Data were acquired by quadrupole ICP-MS after isolation of the REE using an ion-exchange chromatography procedure. All the measured REE abundances are similar ...

متن کامل

Determination of challenging elements in ultrapure semiconductor grade sulfuric acid by Triple Quadrupole ICP-MS

The relatively recent technology of collision/reaction cell (CRC) has become widely used with quadrupole ICP-MS (ICP-QMS) to remove polyatomic ions, which can cause problematic spectral interferences on analytes in complex matrices. By utilizing CRC, background equivalent concentrations (BECs) can be reduced to the ppt or sub-ppt level for almost all elements in semiconductor grade chemicals. I...

متن کامل

Simultaneous determination of trace elements in minute samples by electrothermal-vaporization/low-pressure helium-ICP-MS.

Electrothermal vaporization with two filaments was studied for low-pressure helium-ICP-MS. A 10-microl volume of sample was dried and vaporized, and then introduced to the ICP. With this technique, four elements were simultaneously determined with the acceptable precisions (RSD ca. 10%). The detection limit based on 3sigma of background signals approached the fractional ppb range. The proposed ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Аналитика и контроль

سال: 2016

ISSN: 2073-1442,2073-1450

DOI: 10.15826/analitika.2016.20.3.003