Differential optical-path approach to improve signal-to-noise ratio of pulsed-laser range finding
نویسندگان
چکیده
منابع مشابه
Squeezing the local oscillator does not improve signal-to-noise ratio in heterodyne laser radar.
The signal-to-noise ratio for heterodyne laser radar with a coherent target-return beam and a squeezed local-oscillator beam is lower than that obtained using a coherent local oscillator, regardless of the method employed to combine the beams at the detector.
متن کاملEffect of signal to noise ratio on the speech perception ability of older adults
Background: Speech perception ability depends on auditory and extra-auditory elements. The signal-to-noise ratio (SNR) is an extra-auditory element that has an effect on the ability to normally follow speech and maintain a conversation. Speech in noise perception difficulty is a common complaint of the elderly. In this study, the importance of SNR magnitude as an extra-auditory effect on speech...
متن کاملSignal-to-noise ratio in chirped laser dispersion spectroscopy.
Quantitative studies and experimental validation of noise sources occurring in chirped laser dispersion spectroscopy (CLaDS) are reported. Their impact on the signal-to-noise ratio (SNR) achievable with the CLaDS sensing method is analyzed through a noise model supported by experimental results. In particular the model shows that the SNR is optimal for a given value of the laser chirp rate. The...
متن کاملSignal-to-noise ratio in squeezed-light laser radar.
The formalism for computing the signal-to-noise ratio (SNR) for laser radar is reviewed and applied to the tasks of target detection, direction finding, and phase-change estimation with squeezed light. The SNR for heterodyne detection of coherent light using a squeezed local oscillator is lower than that obtained using a coherent local oscillator. This is true for target detection, for phase es...
متن کاملComputational signal-to-noise ratio analysis for optical quadrature microscopy.
Optical quadrature microscopy (OQM) was invented in 1997 to reconstruct a full-field image of quantitative phase, and has been used to count the number of cells in live mouse embryos. Here we present a thorough SNR analysis that incorporates noise terms for fluctuations in the laser, aberrations within the individual paths of the Mach-Zehnder interferometer, and imperfections within the beamspl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Optics Express
سال: 2014
ISSN: 1094-4087
DOI: 10.1364/oe.22.000563