Digital Test Method for Embedded Converters with Unknown-Phase Harmonics
نویسندگان
چکیده
منابع مشابه
Three-Phase to Single-Phase Matrix Converters: New Topology Based on New Control Method
In this paper, a new topology is proposed for three-phase to single-phase matrix converters, where more voltage levels are produced in the output in comparison with the conventional topologies. In addition, a new control method based on minimum error between the generated and the desired output voltages is proposed for three-phase to single-phase matrix converters. In the proposed control metho...
متن کاملA New Pulsating Power Elimination Method for Single-Phase PWM AC/DC Converters with Minimum Voltage and Current Stress
An inherent problem of single-phase rectifiers is the existence of a pulsating portion in the input power, which pulsates at twice the grid frequency. If this pulsating power is transferred to the DC-link, it causes a significant amount of second-order harmonic at the output voltage. Since in many applications, such a high level of DC oscillation is not acceptable, so the pulsating power must b...
متن کاملDesign of a Digital Voltage Controller in Single-Phase Grid-Connected Renewable Converters
Power decoupling of pulsating grid side power from constant source side power is one of the paramount issues in single phase-phase grid-connected renewable systems. The principal aim of such systems is the decrease of the capacitance of the decoupled capacitor. However, this causes some problems such as an increase in the total harmonic distortion (THD) of injected current to the grid and bus v...
متن کاملThe Test of the Ad Converters Embedded on Two Microcontrollers
Testing method of ADC’s implemented on microcontroller chips are descibed in the paper. The achieved results for microcontroller AT90S8535 and ADuC812 are discussed too. As a criterion of ADC precision, which allows to determine the operational condition limits, the number of effective bits has been chosen. More over, the DNL and INL measured characteristics are presented. The results are compa...
متن کاملSimple digital test approach for embedded charge-pump phase-locked loops - Electronics Letters
system the time constant of which is mainly related to the dumping resistance of the RLC series branch in the equivalent circuit. A second pole is introduced by the rectifier [6], so the whole system could be approximated by a two pole transfer function. Note that the PWM modulator moves the negative slope edge of the input voltage signal changing the duty cycle and consequently the amplitude o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Electronic Testing
سال: 2011
ISSN: 0923-8174,1573-0727
DOI: 10.1007/s10836-011-5194-y