Direct and replacement ion chromatography with potentiometric detection using a silver/silver bromide electrode

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Selective Membrane Electrode for Bromide Ion Based on Aza Pyrilium Ion Derivative as a new Ionophore.

A highly selective electrode for Bromide ion based on aza pyrilium derivative as an excellentionophore is described.The sensor exhibits a good linear response with a slope of ( 60±1 ) mV per decadeover the concentration range of ( 1×10-3 – 9×10-6 M ) , and a detection limit of ( 3×10-6 M ) of Bromideions .The electrode response is independent of pH in the range of(4.0 –9.5).Selectivity coeffici...

متن کامل

Direct potentiometric measurement of potassium in blood serum with liquid ion-exchange electrode.

A new liquid ion-exchange electrode is described which has a selectivity for K-i-over Na of 93:1 in 0.1 mol/kg solutions. Its response is Nernstian in the range 5 X 10 to 5 X lU_i mol KCl per kg. The dip-type electrode responds to small changes in K-in mixed salt solutions containing the same quantities of KCI and NaCI as human blood serum. A miniaturized form of the electrode was adapted to a ...

متن کامل

Direct Determination of Bromide, Nitrate, and Iodide in Saline Matrixes Using Electrostatic Ion Chromatography with an Electrolyte as Eluent

Division of Chemistry, Graduate School of Science, Hokkaido University, Sapporo 060, Japan, School of Chemistry, University of Tasmania, GPO Box 252-75, Hobart 7001, Australia, Division of Material Science, Graduate School of Environmental Earth Science, Hokkaido University, Sapporo 060, Japan, National Industrial Research Institute of Nagoya, 1-1 Hirate-cho, Kita-ku, Nagoya 462-8510, Japan, Au...

متن کامل

A Novel Carbon Paste Electrode for Potentiometric Determination of Vanadyl Ion

Carbon paste electrode was modified by disodium 2,4-diamino-7-methylbenzo[g] pteridine-5,10-dioxide to fabricate a sensor for potentiometric determination of vanadyl ion (VO2+) in aqueous medium. The new ligand was synthesized in three steps with high yield. The optimal composition of the carbon paste was made of graphite powder (64.5%), ionophore (16.6%), paraffin oil (17.8%), a...

متن کامل

Application of a dioxime-PVC electrode to potentiometric studies of Cr(III) ion

A PVC membrane Cr(III) ion selective electrode has been constructed using 2H-1,4-benzothioazine-2,3(4H)dione dioxime (BTD) as membrane carrier. The influence of membrane composition on the electroderesponse was studied. The electrode exhibits a Nernstian response over a Cr(III) concentration range of 1.0 x10 6 to 1.0>< 10-1 M (r = 0.99) with a slope of 19.5 ± 0.5 mV per decade of concentration,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Analytica Chimica Acta

سال: 1989

ISSN: 0003-2670

DOI: 10.1016/s0003-2670(00)81884-x