Dissociation constants and pH-titration curves at constant ionic strength from electrometric titrations in cells without liquid junction: titrations of formic acid and acetic acid
نویسندگان
چکیده
منابع مشابه
Separation of Formic Acid from Aqueous Solutions by Liquid Extraction Technique at Different Temperatures
In this study, the separation of formic acid from aqueous solutions was investigated. Liquid-liquid equilibrium (LLE) data including tie-lines was reported for water + formic acid + 2-methylpropyl ethanoate ternary mixture at (293.15 to 323.15) K and atmospheric pressure. The system shows type-I phase behavior based on Treybal’s classification because only one partially miscible binary mixture ...
متن کاملAcylation of hydrazides with acetic acid and formic acid.
In peptide synthesis, hydrazides are important intermediates for the azide coupling method. A hydrazide is converted to the corresponding azide in the presence of an acid and a nitrite. When acetic acid (or formic acid) is used as the acid, partial acetylation (or formylation) of the hydrazide occurs as a side reaction. Formylation of the hydrazide is much faster than acetylation. Removal of th...
متن کاملInvestigation of the Specific Ion Interactions and Determining Protonation Constant of 3,5-Dihydroxy-2-(3,4,5-trihydroxybenzoyl)oxy-6-[(3,4,5-trihydroxybenzoyl)oxymethyl] oxan-4-yl] 3,4,5-trihydroxybenzoate at Different Ionic Strength
In this research, the protonation constant value of tannic acid was determined at 25 °C and different ionic strengths (0.1 to 0.7 mol/dm3 NaCl) using potentiometric titration technique. The dependence of protonation constant on ionic strength was modeled and discussed by a Debye-Hückel type equation. Then, based on the obtained data from experiments, the minimizing Sum o...
متن کاملA fully automatic system for acid-base coulometric titrations
An automatic system for acid-base titrations by electrogeneration of H(+) and OH(-) ions, with potentiometric end-point detection, was developed. The system includes a PC-compatible computer for instrumental control, data acquisition and processing, which allows up to 13 samples to be analysed sequentially with no human intervention.The system performance was tested on the titration of standard...
متن کاملInvestigation of Volumetric and Acoustic Properties of Ionic Liquid + Amino Acid + Water Systems at Different Temperatures
This paper reports density and speed of sound data for solutions of the ionic liquids (ILs) [C4mim]Cl and [C4mim][CF3SO3] in aqueous solution of 0.05 w/w amino acids of alanine, serine and proline at T = (288.15, 298.15, 308.15 and 318.15) K. From the experimental data measured, the apparent molar volume (Vϕ), isentropic compressibility ( ), and apparent molar isentropic compression ( ) have be...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Research of the National Bureau of Standards
سال: 1943
ISSN: 0091-0635
DOI: 10.6028/jres.030.025