Dose Verification in Intensity Modulation Radiation Therapy: A Fractal Dimension Characteristics Study

PURPOSE This study describes how to identify the coincidence of desired planning isodose curves with film experimental results by using a mathematical fractal dimension characteristic method to avoid the errors caused by visual inspection in the intensity modulation radiation therapy (IMRT). METHODS AND MATERIALS The isodose curves of the films delivered by linear accelerator according to Pla...

متن کامل

Dosimetric verification of pre-treatment intensity modulated radiation therapy in the commissioning process

Background: Commissioning tests are recommended before implementing Intensity Modulated Radiation Therapy. This study evaluated five different plans of IMRT mocks for different modulation indices. Materials and Methods: IMRT tests were done in slab phantom for both 6MV and 15 MV photon energies using a 2D array ion chamber dosimeter. Results: The acceptance criteria were based on 3% /3mm. All t...

متن کامل

Enhancing and verification of dose in external radiation therapy using Gd nanoparticles as a theranostic agent: A Monte Carlo simulation study

Introduction: Theranostics, in particular, the use of radionuclides with the capability of simultaneous imaging and treatment has opened new horizons in personalized treatment planning of targeted radiation therapy. In this approach, positive beta or gamma emitters are required for imaging and alpha, beta and Auger electrons for treatment purpose. On the other hand, studies hav...

متن کامل

Dose verification of helical tomotherapy intensity modulated radiation therapy planning using 2D-array ion chambers

PURPOSE To investigate the clinical usage of dose verification of Helical Tomotherapy plans by using 2D-array ion chambers, and to develop an efficient way to validate the dose delivered for the patients during treatments. MATERIALS AND METHODS A pixel-segmented ionisation chamber device, IMRT MatriXX™ and Multicube™ phantom from IBA were used on ten selected Tomotherapy IMRT/IGRT head and ne...

متن کامل

Intensity‐modulated radiation therapy dose verification using fluence and portal imaging device

Patient-specific quality assurance for intensity-modulated radiation therapy (IMRT) dose verification is essential. The aim of this study is to provide a new method based on the relative error distribution by comparing the fluence map from the treatment planning system (TPS) and the incident fluence deconvolved from the electronic portal imaging device (EPID) images. This method is validated fo...