EFFECTS OF GEOMETRIC PARAMETERS FOR WAVY FINNED-TUBE HEAT EXCHANGER IN TURBULENT FLOW: A CFD MODELING
نویسندگان
چکیده
منابع مشابه
Effects of Geometric Parameters for Wavy Finned-tube Heat Exchanger in Turbulent Flow: a Cfd Modeling
In this study, the effects of thermal and hydraulic characteristics of wavy fin and tube heat exchanger are investigated. Simulation has been carried out by a commercial computational fluid dynamics code, ANSYS CFX12.0. The main objective of this study is to investigate the flow characteristics in turbulent flow. Results are predicted for the turbulent flow regime (2100≤Re≤7000) and compared wi...
متن کاملMinimization of Entransy Dissipations of a Finned Shell and Tube Heat Exchanger
Improving heat transfer and performance in a radial, finned, shell and tube heat exchanger is studied in this study. According to the second law of thermodynamics, the most irreversibilities of convective heat transfer processes are due to fluid friction and heat transfer via finite temperature difference. Entransy dissipations are due to the irreversibilities of convective heat transfer. There...
متن کاملNumerical Studies on the Performance of Finned-Tube Heat Exchanger
Finned-tube heat exchangers are predominantly used in space conditioning systems, as well as other applications requiring heat exchange between two fluids. The design of finned-tube heat exchangers requires the selection of over a dozen design parameters by the designer such as tube pitch, tube diameter, tube thickness, etc... Finned-tube heat exchangers are common devices; however, their perfo...
متن کاملThe Effects of Frost Formation in a Flat Plate Finned-Tube Heat Exchanger
An experimental study on the effects of various factors(fin spacing, fin arrangement, air temperature, air humidity, and air velocity) on the frost growth and thermal performance of a finned-tube heat exchanger has been conducted under the frosting condition. It is found that the thermal performance of a heat exchanger is closely related to the blockage ratio of air flow passage due to the fros...
متن کاملTheoretical Study of Indirect Heating Temperature Swing Adsorption in an Adsorbent Coated Finned Tube Heat Exchanger
In this study, the performance of an adsorbent coated finned tube exchanger for carbon capture was investigated numerically. The results showed that this structure has a great potential for being applied as a medium for CO2 capture by rapid indirect thermal swing adsorption. By using this structure, the recovery of 96%, and purity of 98% were achieved with a simple cycle consisting of two steps...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Frontiers in Heat and Mass Transfer
سال: 2015
ISSN: 2151-8629
DOI: 10.5098/hmt.6.5