<span lang="EN-US">Stand-alone low voltage (LV) microgrids supplying small local loads far from the utility grid are becoming an increasingly popular alternative to a total reliance on centralized grid. In most of LV microgrids, three-phase four-wire distribution systems used supply both single- and loads. Unequal can result in unbalance problems. The use four-leg inverter is one best solutions for providing neutral current path compensating unbalanced load conditions stand-alone microgrids. This paper proposes fast control technique compensate operating microgrid. suggested provides controller’s orthogonal component without introducing any additional dynamics or distortions. major benefits recommended per-phase over conventional signal generation (OSG) methods enhanced steady-state dynamic performances as well independency system parameters. Several simulation results provided confirm superior performance methods.</span>
منابع مشابه
A New Dead Time Compensation method for Stand - alone Inverter under Unbalanced Loads
phase stand-alone inverter is caused by unbalanced load and a dead time distorts inverter output voltage more unsymmetrically. When the inverter supplies unbalanced load, three phase output voltages include unbalanced odd harmonics but dq-axis voltages at synchronous reference frame have even harmonics with different magnitude each other. In this paper, a new compensation method is proposed to ...
متن کاملOperation of Stand Alone PV Generating System for Supplying Unbalanced AC Loads
This paper describes a DC isolated network which is fed with Distributed Generation (DG) from photovoltaic (PV) renewable sources for supplying unbalanced AC loads. The battery energy storage bank has been connected to the DC network via DC/DC converter to control the voltage of the network and optimize the operation of the PV generation units. The PV arrays are connected to the DC network ...
متن کاملPower Quality Improvement in a Speed Sensorless Stand-alone DFIG Feeding General Unbalanced Non-linear Loads
This paper reports the performance of a speed sensorless stand-alone Variable Speed Constant Frequency (VSCF) Doubly Fed Induction Generator (DFIG) capable of supplying all types of loads. The proposed method maintains the Total Harmonic Distortion (THD) of the machine current and the load voltage within acceptable limits. In contrast to previously proposed methods, in this paper, the stator si...
متن کاملPerformance analysis for DFIG Feeding a Stand-alone Unbalanced Load
In this paper, a control system for the operation of a doubly fed induction generator (DFIG), feeding an unbalanced three-phase load is presented. The load unbalance is compensated using the front-end converter. The control system is based on positive and negative sequence components of current. MATLAB Simulation results obtained from a DFIG system and are presented and discussed in this paper....
متن کاملAn Effective Rotor Current Controller for Unbalanced Stand-Alone DFIG Systems in the Rotor Reference Frame
This paper presents an effective rotor current controller for variable-speed stand-alone doubly fed induction generator (DFIG) systems feeding an unbalanced three-phase load. The proposed current controller is developed based on proportional plus two resonant regulators, which are tuned at the positive and negative slip frequencies and implemented in the rotor reference frame without decomposin...