Evaluation of slice thickness and inter slice distance in MR scanning using designed test tool
نویسندگان
چکیده
منابع مشابه
Step Interpolation of MR Images with Inter-Slice Gap Correction
This report describes the design of an algorithm for the binary up-interpolation of normal structural MR data in the through slice direction. The method is intended as a pre-processing stage for the measurement of cortical thickkness, where data has already been acquired at lower resolution than would have been ideal. More work is still needed to quantify performance, though a theroetical evalu...
متن کاملMRI Inter - slice Reconstruction
MRI reconstruction using super-resolution is presented and shown to improve spatial resolution in cases when spatially-selective RF pulses are used for localization. In 2-D multislice MRI, the resolution in the slice direction is often lower than the in-plane resolution. For certain diagnostic imaging applications, isotropic resolution is necessary but true 3-D acquisition methods are not pract...
متن کاملProcedures for Evaluation of Slice Thickness in Medical Imaging Systems
The main goal of a medical imaging system is to produce images to provide more accurate and timely diagnoses (Torfeh et al., 2007). In particular, Computed Tomography (CT), Magnetic Resonance Imaging (MRI), and Ultrasound (US) are resourceful tools in medical practice, and in many cases a life saving resource when rapid decisions are needed in the emergency room (Rehani et al., 2000). The above...
متن کاملImplementation of an Automatic Slice-to-Slice Registration Tool
This paper outlines the basic steps in the design and implementation of a feature based Transmission Electron Microscopy (TEM) image registration application and highlights some of the implementation details, such as the detection of features, feature descriptor design, robust filtering of mismatched descriptors, and transform estimation. Although the approach chosen is based on the Scale Invar...
متن کاملBrain slice holder for MR.
We made an MR-compatible brain slice holder that ensures that the images have the same location and orientation as the subsequent histologic sections. This device encloses the unfixed tissues, thus reducing the danger of exposure to pathogens. MR imaging time is saved by scanning selected slices rather than the whole brain; this technique is especially useful when brain sections at varying angl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Indian Journal of Radiology and Imaging
سال: 2005
ISSN: 0971-3026
DOI: 10.4103/0971-3026.28758