Experience with a static magnetostrictive readout system for wire chambers
نویسندگان
چکیده
منابع مشابه
Wire Arrays Vs Vidicons: a Comparison of Large Wire Arrays with Optical Spark Chambers Using Vidicon Readout
Digitized spark-chamber systems using wire arrays are being used for increas ingly complex types of events; their chief virtue is the provision of "on-line II informa tion on the progre ss of the experiment, which we inte rpret as rapid enough to aIIow the results obtained to influence the future course of the experiment. Such on-line operation can also be obtained by several other methods fo...
متن کاملA New Single Wire Readcut System-for Spark Chambers*
A new, conceptually very simple, single wire readout system for spark chambers in strong magnetic fields is described. (Submitted to Nucl. Instr. and Methods. ) *Work supported in part by the U. S. Atomic Energy Commission. Prepared under Contracts AT(04-3)-5 15 and AT(ll-l)-68 for the San Francisco Operations Office, U. S. Atomic Energy Commission.
متن کاملNew Developments in the Magnetostrictive Readout System at Slac*
The present paper describes the work done at SLAC for the magnetostrictive wire spark chambers of SPEAR, LASS and the two-meter streamer chamber. All three are CAMAC systems based on the use of a time digitizer module with different interfacing techniques into three different computers (Sigma 5, PDP-9, PDP-11). Of particular interest is a display controller module that permits wide selection of...
متن کاملT-racking with Wire Chambers at High Luminosities*
Radiation damage and rate limitations impose severe constraints on wire chambers at the SSC. Possible conceptua1 designs for wire chamber tracking systems that satisfy these constraints are discussed. Computer simulation studies of tracking in such systems are presented. Simulations of events from interesting physics at the SSC, including hits from minimum bias background events, are examined. ...
متن کامل- iii - LIQUID XENON FILLED WIRE CHAMBERS FOR MEDICAL IMAGING
In 1968, Luis Alvarez suggested that a high-resolution multiwire particle detector could be developed using a thin layer of liquified noble gas as the detection medium. After key problems in chamber construcbon, purification, and readout had been solved, a spatial resolution of 15 fl. rms was demonstrated. Work is in progress to build high-resolubon chambers and lTIeasure their properties for p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Nuclear Instruments and Methods
سال: 1971
ISSN: 0029-554X
DOI: 10.1016/0029-554x(71)90041-3