Experimental and analytical performance investigation of air to air two phase closed thermosyphon based heat exchangers

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental Investigation of Boiling and Condensation Heat Transfer of a two Phase Closed Thermosyphon

In this paper the heat transfer characteristics of a two-phase closed thermosyphon over a wide range of heat transfer rates, system pressure, aspect ratios and filling ratios were studied. The experiments focused on the boiling and condensation heat transfer characteristics of the thermosyphon. The experimental boiling and condensation heat transfer coefficients inside the thermosyphon were com...

متن کامل

Experimental Investigation of Boiling and Condensation Heat Transfer of a Two Phase Closed Thermosyphon

In this paper the heat transfer characteristics of a two-phase closed thermosyphon over a wide range of heat transfer rates, system pressure, aspect ratios and filling ratios were studied. The experiments focused on the boiling and condensation heat transfer characteristics of a thermosyphon with a copper tube having 25 and 32 mm inside and outside diameters. Distilled water was used as the wor...

متن کامل

Experimental investigation of a solar desalination performance based on humidification-dehumidification technique with air and water closed cycle

In this study, the performance of solar desalination by humidification-dehumidification of closed air and water in Ahvaz city was investigated. This desalination includes a collector, condenser, salty water, freshwater tanks, air blower, and water pump. The evaluation of the system was done at three levels of air velocity (3, 4, and 5 m/s) and at three pump discharge levels (2, 4, and 6 liters/...

متن کامل

Experimental and simulation study on the air side thermal hydraulic performance of automotive heat exchangers

Flat tube heat exchangers with louvered fins were applied in order to meet the performance requirements and compactness in automotive air conditioning systems. Experimental and simulation study focusing on the air side thermal hydraulic performance of automotive heat exchangers were performed in this article. Test results showed that the heat capacity of a condenser with 5.4 mm height louvered ...

متن کامل

Two-phase Closed Thermosyphon with Nanofluids

Nanofluids, stabilized suspensions of nanoparticles typically < 100 nm in conventional fluids, are evolving as potential enhanced heat transfer fluids due to their better thermal conductivity, increase in single phase heat transfer coefficient and significant increase in critical boiling heat flux. In the present paper, we investigate the overall thermal resistance of a closed two-phase thermos...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Energy

سال: 2014

ISSN: 0360-5442

DOI: 10.1016/j.energy.2014.04.107