EXPERIMENTAL STUDY ON DEFORMATION CAPACITY OF FIELD WELDING BEAM TO COLUMN JOINT WITH DIFFERENT BEAM END DETAILS
نویسندگان
چکیده
منابع مشابه
Evaluation of Column-Tree Moment Resisting Connection with End Plates and Haunched Beam (RESEARCH NOTE)
The column-tree constructional schemes allows for a reliable and convenient erection of moment resisting steel frames. Strengthening of column-tree connection with a haunch part can significantly improve seismic behavior of whole system. In the current study behavior of column-tree connections with haunched beams and end plate splices have been investigated. Special attention was paid for evalu...
متن کاملAnalytical and Experimental Investigation of I Beam-to-CFT Column Connections under Monotonic Loading (RESEARCH NOTE)
In this study, the behavior characteristics of I beam-to-concrete filled tube (CFT) column connection is studied through experiment and finite element models under the monotonic loading. To validate the finite element modeling, at first, an experimental model is made and experimented. After validation of the finite element modeling, different models were created in the software. The studied par...
متن کاملRetrofitting of Beam-Column Joint Using CFRP and Steel Plate
─This paper presents the retrofitting of beam-column joint using CFRP (Carbon Fiber Reinforced Polymer) and steel plate. This specimen was tested until failure up to 1.0% drift. This joint suffered severe damages and diagonal cracks at upper crack at upper column before retrofitted. CFRP were wrapped at corbel, bottom and top of the column. Steel plates with bonding were attached to the two bea...
متن کاملAn Analytical Study on Rotational Capacity of Beam-Column Joints in Unit Modular Frames
Modular structural systems are constructed using a method that they are assembled with prefabricated unit modular frames on-site. This provides a benefit that can significantly reduce building construction time. The structural design is usually carried out under the assumption that their load-carrying mechanism is similar to that of traditional steel moment-resisting systems. However, both syst...
متن کاملA Study on the Ductility of Bolted Beam - Column Connections
The behaviour of beam-column joint plays an important role in the response of a steel moment resisting framed structure especially under seismic excitation. Semi rigid connections like bolted joints, allow better energy dissipation and provide good response under lateral loads. In this paper the ductility and energy dissipation characteristics of semi rigid bolted connections using double web a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: QUARTERLY JOURNAL OF THE JAPAN WELDING SOCIETY
سال: 2019
ISSN: 0288-4771
DOI: 10.2207/qjjws.37.162