Fabrication and Characterization of Ultrathin-ring Electrodes for Pseudo-steady-state Amperometric Detection.

The fabrication of ultrathin-ring electrodes with a diameter of 2 mm and a thickness of 100 nm is established. The ultrathin-ring electrodes provide a large density of pseudo-steady-state currents, and realize pseudo-steady-state amperometry under quiescent conditions without a Faraday cage. Under the limiting current conditions, the current response at the ultrathin-ring electrode can be well ...

متن کامل

Fabrication of amperometric electrodes.

Carbon fiber electrodes are crucial for the detection of catecholamine release from vesicles in single cells for amperometry measurements. Here, we describe the techniques needed to generate low noise (<0.5 pA) electrodes. The techniques have been modified from published descriptions by previous researchers (1,2). Electrodes are made by preparing carbon fibers and threading them individually in...

متن کامل

Fabrication of nanoindented electrodes for glucose detection.

BACKGROUND The objective of this article was to design, fabricate, and evaluate a novel type of glucose biosensors based on the use of atomic force microscopy to create nanoindented electrodes (NIDEs) for the selective detection of glucose. METHODS Atomic force microscopy nanoindentation techniques were extended to covalently immobilized glucose oxidase on NIDEs via composite hydrogel membran...

متن کامل

Fabrication and Characterization of Graphene Electrodes for Electrochemistry Experiments

The goal of our project is to pattern well-defined electrodes from single-layer graphene for use in electrochemistry investigations. We have fabricated devices using both mechanically exfoliated graphene and chemical vapor deposition (CVD) graphene. Preliminary experimental data show that the graphene is chemically clean, based on measurements that the effective area of the electrodes determine...

متن کامل

Amperometric Oxygen Electrodes

Although the Winkler method is very precise when performed with strict control of pH and iodine concentration, it is still susceptible to errors. For example, ions such as Fe2+ and SO3-, suspended solids, and some organics can produce gross inaccuracies. There have been numerous modifications of the method over the years to compensate for its shortcomings (2). Besides the errors inherent in the...