Fast Simultaneous Determination of Niobium and Tantalum by Kalman Filter Analysis with Flow Injection Chemiluminescence Method

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Flow injection chemiluminescence analysis for highly sensitive determination of noscapine

Noscapine is an antitussive drug and possesses potent antitumor activity. This work establishes a highly sensitive method for its determination by flow injection chemiluminescence (CL) technique. This method is based on its strong sensitizing effect on the weak CL reaction between sulfite and acidic permanganate. The mechanism for the sensitizing process is proposed on the basis of fluorescence...

متن کامل

multiwavelength pectrophotometric determination of stability constants of 4-(2– thiazolylazo) resorcinol (tar) with la3+, y3+ and th4+ in organic-water mixed solvents by chemometrics method & simultaneous spectrophotometric determination of lead, copper and nickel using xylenol orange by partial least squares calibration method

تشکیل کمپلکس های tarبا یون های لانتانیم, ایتریم و توریم در دمای 25 درجه، قدرت یونی ثابت 0.1 مولار و در ph ثابت در مخلوط حلال های اتانول – آب و استونیتریل – آب با استفاده از روش های اسپکتروفوتومتری مورد بحث و بررسی قرار گرفت. داده های اسپکتروفوتومتری با استفاده از نرم افزار squad پردازش شدند تا ثابت های تشکیل کمپلکس اندیکاتور – فلز را محاسبه کند. نتایج نشان می دهد که درصد حلال آلی در مخلوط حلال ...

15 صفحه اول

Determination of phenylephrine hydrochloride by flow injection analysis with chemiluminescence detection.

A new method is proposed for the determination of phenylephrine hydrochloride by flow injection analysis with direct chemiluminescence detection. The method is based on the oxidation of the drug by potassium permanganate in sulfuric acid medium at 80 degrees C. The calibration graph is linear over the range 0.03-8 ppm phenylephrine hydrochloride, with a relative standard deviation (n = 51, 0.5 ...

متن کامل

Simultaneous determination of D-glucose and 3-hydroxybutyrate by chemiluminescence detection with immobilized enzymes in a flow injection system.

A chemiluminometric flow-through sensor for the simultaneous determination of glucose (Glu) and 3-hydroxybutyrate (HB) in a single sample has been developed. Coimmobilized 3-hydroxybutyrate dehydrogenase/NADH oxidase/peroxidase, a support material, and coimmobilized glucose dehydrogenase/NADH oxidase/peroxidase were packed sequentially in a transparent PTFE tube. The tube was then placed in fro...

متن کامل

Chemiluminescence determination of carbofuran at trace levels in lettuce and waters by flow-injection analysis.

A simple, fast chemiluminescence (CL) flow-injection (FI) method based on the reaction of luminol with KMnO(4) in alkaline medium has been described for the direct determination of carbofuran. The method is based on the enhancing effect in the emission light from the oxidation of luminol produced in presence of carbofuran. The optimisation of instrumental and chemical variables influencing the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Analytical Sciences

سال: 2005

ISSN: 0910-6340,1348-2246

DOI: 10.2116/analsci.21.1051