Fetal MEG evoked response latency from beamformer with random field theory
نویسندگان
چکیده
منابع مشابه
Realistic spatial sampling for MEG beamformer images.
The spatial resolution achievable using magnetoencephalography (MEG) beamformer techniques is inhomogeneous across the brain and is related directly to the amplitude of the underlying electrical sources [Barnes and Hillebrand, Hum Brain Mapp 2003;18:1-12; Gross et al., Proc Natl Acad Sci USA 2001;98:694-699; Van Veen et al., IEEE Trans Biomed Eng 1997;44:867-860; Vrba and Robinson, Proc 12th In...
متن کاملLatency of MEG Ml00 Response Indexes First Formant Frequency
Magnetoencephalographic recordings from the auditory cortex of subjects show a close correlation between the timing of the evoked Ml00 response and the first formant frequency (Fl) of vowels and vowel-like stimuli. These results are compatible with evoked magnetic field latencies elicited by tone stimuli, which show 100-300 Hz tones associated with latencies up to 30 ms longer than 500-3000 Hz ...
متن کاملLatency of MEG M100 Response Indexes First Formant Frequency
Magnetoencephalographic recordings from the auditory cortex of subjects show a close correlation between the timing of the evoked M100 response and the first formant frequency (F1) of vowels and vowel-like stimuli. These results are compatible with evoked magnetic field latencies elicited by tone stimuli, which show 100-300 Hz tones associated with latencies up to 30 ms longer than 500-3000 Hz ...
متن کاملA comparison of random field theory and permutation methods for the statistical analysis of MEG data.
We describe the use of random field and permutation methods to detect activation in cortically constrained maps of current density computed from MEG data. The methods are applicable to any inverse imaging method that maps event-related MEG to a coregistered cortical surface. These approaches also extend directly to images computed from event-related EEG data. We determine statistical thresholds...
متن کاملA general linear model for MEG beamformer imaging.
A new general linear model (GLM) beamformer method is described for processing magnetoencephalography (MEG) data. A standard nonlinear beamformer is used to determine the time course of neuronal activation for each point in a predefined source space. A Hilbert transform gives the envelope of oscillatory activity at each location in any chosen frequency band (not necessary in the case of sustain...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: NeuroImage
سال: 2010
ISSN: 1053-8119
DOI: 10.1016/j.neuroimage.2009.08.019