Finite element analysis of non-Newtonian magnetohemodynamic flow conveying nanoparticles through a stenosed coronary artery
نویسندگان
چکیده
منابع مشابه
Physiological Non-newtonian Blood Flow through Single Stenosed Artery
A numerical simulation to investigate the Non-Newtonian modeling effects on physiological flows in a three dimensional idealized artery with a single stenosis of 85% severity is given. The wall vessel is considered to be rigid. Oscillatory physiological and parabolic velocity profile has been imposed for inlet boundary condition. Determination of the physiological waveform is performed using a ...
متن کاملMathematical modelling of Sisko fluid flow through a stenosed artery
In the present study, the nonlinear model of non-Newtonian blood flow in cosine-shape stenosed elastic artery is numerically examined. The model is carried out for axisymmetric, two-dimensional and fully developed blood flow. The vessel wall is assumed to be have time-dependent radius that is important factor for study of blood flow. The cosine-shape stenosis convert to rigid artery by using a ...
متن کاملMHD Flow of Blood through Radially Non-symmetric Stenosed Artery: a Hershcel-Bulkley Model (RESEARCH NOTE)
The purpose of this study is to develop a mathematical model for studying the magnetic field effect on blood flow through an axially non-symmetric but radially symmetric atherosclerotic artery. Herschel-Bulkley equation has been taken to represent the non-Newtonian character of blood. The response of magnetic field, stenosis height, shape parameter on velocity, volumetric flow rate in stenotic ...
متن کاملModeling of non-Newtonian Blood Flow through a Stenosed Artery Incorporating Fluid-Structure Interaction
This study investigated fluid and structural responses to pulsatile non-Newtonian blood flow through a stenosed artery, using ANSYS. The artery was modeled as an axis-symmetric stenosed vessel. The wall of the vessel was set to be isotropic and elastic. The blood behavior was described by the Power Law and Carreau non-Newtonian models, respectively. When compared to the Newtonian flow models, t...
متن کاملVibration Analysis of Carotid Arteries Conveying Non-Newtonian Blood Flow Surrounding by Tissues
The high blood rate that often occurs in arteries may play a role in artery failure and tortuosity which leads to blackouts, transitory ischemic attacks and other diseases. However, vibration and instability analysis of carotid arteries are lacking. The objective of this study is to investigate the vibration and instability of the carotid arteries conveying blood under axial tension with surrou...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Heat Transfer-Asian Research
سال: 2019
ISSN: 1099-2871