Fixation Stability Measurement Using Two Types of Microperimetry Devices
نویسندگان
چکیده
منابع مشابه
Fixation Stability Measurement Using Two Types of Microperimetry Devices.
PURPOSE We compared the fixation stability measurements obtained with two microperimeters, the Micro Perimeter 1 (MP-1) and the Spectral OCT/SLO (OCT/SLO), in subjects with and without maculopathies. METHODS A total of 41 eyes with no known ocular diseases and 45 eyes with maculopathies were enrolled in the study. Both eyes of each participant had a 20-second fixation test using the MP-1 and ...
متن کاملFixation stability measurement using the MP1 microperimeter.
PURPOSE The Nidek microperimeter (MP1, Nidek Instruments, Italy) is a microperimetry device that also assesses fixation stability. The MP1 does not use the method of quantifying fixation stability by calculating a bivariate contour ellipse area (BCEA). Here we compare the MP1 fixation quantification with the BCEA technique by correlating these values to various parameters of reading known to be...
متن کاملComparison of stability of different types of external fixation.
UNLABELLED Stabilization of fractures by external fixator is based on the mechanical connecting of the pins, screwed into the proximal and distal bone fragment. Site of fracture is left without any foreign materials, which is essential for prevention of infections. Aim of this work is to compare stability of constructs bone model-external fixators of different types (Ortofix, Mitković, Charnele...
متن کاملMeasurement of the immobilisation efficacy of a head fixation system
Background: In order to assign appropriate planning target volume (PTV) margins, each centre should measure the patient positioning deviations for their set-up techniques. At the Royal Marsden Hospital, UK, a conformal shell (cast) system is used when a stereotactic frame is not suitable. In this paper, we report on a series of measurements with the aim of obtaining the systematic and random ...
متن کاملFeasibility of Macular Integrity Assessment (MAIA) Microperimetry in Children: Sensitivity, Reliability, and Fixation Stability in Healthy Observers.
Purpose To assess the feasibility of macular integrity assessment (MAIA) microperimetry (MP) in children. Also to establish representative outcome measures (differential light sensitivity, fixation stability, test-retest reliability) for children without visual impairment. Methods Thirty-three adults and 33 children (9-12 years) were asked to perform three monocular MAIA examinations within a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Translational Vision Science & Technology
سال: 2015
ISSN: 2164-2591
DOI: 10.1167/tvst.4.2.3