Flow Rate Independent Amperometric Flow Cells Using Microhole Array Electrodes

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

New implementation of a non-associated flow rule in rate-independent plasticity

One of the new research fields in plasticity is related to choosing a proper non-associated flow rule (NAFR), instead of the associated one (AFR), to predict the experimental results more accurately. The idea of the current research is derived from combining von Mises and Tresca criteria in the places of yield and plastic potential surfaces in rate-independent plasticity.  This idea is implemen...

متن کامل

Clinical evaluation of amperometric enzyme electrodes in continuous-flow analysis for glucose in undiluted whole blood.

We have evaluated the carbon-paste enzyme/wall-jet electrode in continuous-flow analysis for glucose in undiluted whole blood. Responses of the electrode to protein-based and aqueous samples under wall-jet configuration are described. Imprecision in the flow-injection mode was less than 2% for glucose values in the usual analytical range (1-25 mmol/L). The dynamic range for glucose was from 0.0...

متن کامل

Amperometric Oxygen Electrodes

Although the Winkler method is very precise when performed with strict control of pH and iodine concentration, it is still susceptible to errors. For example, ions such as Fe2+ and SO3-, suspended solids, and some organics can produce gross inaccuracies. There have been numerous modifications of the method over the years to compensate for its shortcomings (2). Besides the errors inherent in the...

متن کامل

Amperometric Oxygen Electrodes

Although the Winkler method is very precise when performed with strict control of pH and iodine concentration, it is still susceptible to errors. For example, ions such as Fe2+ and SO3-, suspended solids, and some organics can produce gross inaccuracies. There have been numerous modifications of the method over the years to compensate for its shortcomings (2). Besides the errors inherent in the...

متن کامل

Amperometric Enzyme Electrodes

Neste trabalho de revisão são analisados os avanços mais recentes em eletrodos enzimáticos amperométricos dando ênfase particular aos biosensores baseados na Glucose Oxidase e na Horseradish Peroxidase. A intermediação redox através de mediadores artificiais solúveis ou ligados a polímeros é discutida em termos dos desenvolvimentos teóricos recentes e verificações experimentais. É analisada a d...