Numerical Modeling of Wet Steam Flow in Steam Turbine Channel
In power station practice, work is extracted from expanding steam in three stages namely High Pressure(HP), Intermediate Pressure(IP) and Low Pressure(LP) turbines. During the expansion process in the LP turbine, the steam cools down and at some stages, it nucleates to become a two-phase mixture. It is well-acknowledged in the literature that the nucleating and wet stages in steam turbines are ...
متن کاملK V Santhosh: Fusion of Venturi and Ultrasonic Flow Meter for Enhanced Flow Meter Characteristics Using Fuzzy Logic
This paper proposes a technique for measurement of liquid flow using venturi and ultrasonic flow meter(UFM) to have following objectives a) to design a multi-sensor data fusion (MSDF) architecture for using both the sensors, b) improve sensitivity and linearity of venturi and ultrasonic flow meter and c) detect and diagnosis of faults in sensor if any. Fuzzy logic algorithm is used to fuse outp...
متن کاملA Curve-fitting Calibration Method applied for Ultrasonic Flow-meter
As the influence of fluid distribution in the internal pipe, the measurement characteristics of theory and practice exist significant differences in Ultrasonic Flow-meter (USF). Through analysis of fluid state, the method of curve-fitting is applied for the calibration of USF. Experimental results show that the USF can achieve level-1 accuracy with just a correction of 5 flow points, and this m...
متن کاملA Signal Pre-processing Algorithm Applied for Ultrasonic Flow-meter
In order to solve the problem of time difference ultrasonic flow meter’s low accuracy, against the basic characteristics of the sample data, a data-processing algorithm is proposed. First, we use shell sort do a data pre-processing to the samples, then remove the error of the sample space by complex digital filter, and use the error compensation algorithm to get the final sample results. Among ...
متن کاملUltrasonic blood flow measurement in haemodialysis.
A 5-megacycle Doppler flow meter, calibrated in-vitro, was found to give a linear response to blood flow in the ranges commonly encountered in haemodialysis. With this, blood flow through artificial kidneys could be measured simply and with a clinically acceptable error. The method is safe, as blood lines do not have to be punctured or disconnected and hence there is no risk of introducing infe...