Fully adiabatic 31 P 2D-CSI with reduced chemical shift displacement error at 7 T - GOIA-1D-ISIS/2D-CSI

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Chemical shift imaging (CSI) by precise object displacement.

A mechanical device (NMR lift) has been built to displace vertically an object (typically an NMR sample tube) inside the NMR probe with an accuracy of 1 microm. A series of single pulse experiments are performed for incremented vertical positions of the sample. With a sufficiently spatially selective radio-frequency (r.f.) field, one obtains chemical shift information along the displacement dir...

متن کامل

Natural linewidth chemical shift imaging (NL-CSI).

The discrete Fourier transform (FT) is a conventional method for spatial reconstruction of chemical shifting imaging (CSI) data. Due to point spread function (PSF) effects, FT reconstruction leads to intervoxel signal leakage (Gibbs ringing). Spectral localization by imaging (SLIM) reconstruction was previously proposed to overcome this intervoxel signal contamination. However, the existence of...

متن کامل

Imaging Creatine Kinase Reaction Activity in Human Brain using 3D 31P CSI CSI at 7 Tesla

X. Zhu, H. Qiao, X. Zhang, H. Lei, W. Chen Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, Minnesota, United States SYNOPSIS In vivo 3D P chemical shift imaging (CSI) was performed on entire human brain using a H/P double-tuned TEM volume coil at 7 Tesla. Excellent P NMR sensitivity was achieved with voxel size of 15.5 ml. The P CSI approach was incorporated with t...

متن کامل

SNR Maximization at CSI Aware AF Relay

This paper concerns two-hop communication over relay-assisted Block fading channel. It is assumed there is not a direct link between the transmitter and the affiliated destination and the communication occurs in two hops through the use of a relay, where the amplify and forward (AF) strategy is employed at this node. In this case, in a Rayleigh block fading channel, the optimal weight function ...

متن کامل

CSI: Bethesda

Summarn Recognition of psychological distress in patients with cancer. some of which can be ameliorated With appropriate intervention. is a crucial aspect of patient care. Previous studies, with the exception of one. indicate that oncologists often fail to detect general distress and do not identify those patients with significant psychological disorder. As approximately 25-30% of patients expe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Magnetic Resonance in Medicine

سال: 2012

ISSN: 0740-3194

DOI: 10.1002/mrm.24363