Fully integrated 3D high-resolution multicontrast abdominal PET-MR with high scan efficiency
نویسندگان
چکیده
منابع مشابه
treating refractory hypertension: renal denervation with high-resolution 3d-angiography
a 53-year-old male was referred to our department for refractory primary hypertension. despite high doses of 6 anti-hypertensive drugs, ambulatory monitoring of blood pressure (bp) revealed a mean bp of 160/90 mmhg. under local anaesthesia, renal denervation with radiofrequency was performed supported by high-resolution 3d angiography, which helped confirm the position of the applications in a ...
متن کاملHigh-resolution 3D MR imaging of the trochlear nerve.
BACKGROUND AND PURPOSE The cisternal segment of the trochlear nerve is difficult to identify reliably by routine MR imaging. We investigated the visibility and anatomic features of the trochlear nerve by using high-resolution 3D-bTFE imaging in healthy subjects. MATERIALS AND METHODS This study was conducted with 32 healthy subjects without ocular movement disorders. For us to visualize the c...
متن کاملIntegrated high-resolution tomography
A common problem in seismic tomography is the inadequate amount of data required for accurate traveltime inversion. The inherent nature in which data is acquired and the subsurface velocities of the survey area can result in a nonuniform distribution of raypaths. In such instances the statistical nature of tomographic inversion biases the solution to reflect the acquisition instead of the geolo...
متن کاملFully-Automated 3D Metrology and Defect Analysis with High-Resolution 300 kV Microfocus Computed Tomography
With industrial X-ray computed tomography (CT), even low-contrast defects in cast parts, such as cracks, pores and blowholes, can be localized and measured in three dimensions. Analysis of the defects can be performed using either multi-positional 2D cross-section planes or the 3D volume view. Additionally, 3D metrology with CT becomes more and more an effective tool for many tasks in productio...
متن کاملبررسی حساسیت، ویژگی و صحت تشخیصی High Resolution CT Scan در آسیبهای منیسک
زمینه و هدف: مفصل زانو بهعنوان بزرگترین مفصل سینوویال بدن شامل رباطهای جانبی، رباطهای متقاطع و منیسک داخلی و خارجی میباشد. برای مدیریت مناسب، شناسایی آسیب به هریک از ساختارهای زانو ضروری است. در این مطالعه حساسیت، ویژگی و صحت تشخیصی High Resolution CT Scan در آسیبهای منیسک بررسی گردید. روش بررسی: در این مطالعه ارزیابی صحت آزمون، 57 بیمار با شرح حال مثبت ضایعه منیسک مراجعهکننده به بیمارستا...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Magnetic Resonance in Medicine
سال: 2017
ISSN: 0740-3194
DOI: 10.1002/mrm.26757