Functional and radiological outcome in distal radius fractures treated with locking compression plate
نویسندگان
چکیده
منابع مشابه
Functional Results of Unstable (Type 2) Distal Clavicle Fractures Treated with Superior Anterior Locking Plate
Background: The treatment of distal clavicle fracture is always a challenge, as it is mostly unstable and has higherrate of delayed union, malunion, non-union and associated acromioclavicular arthritis. So the management of thesefractures remains controversial. The purpose of this study is to evaluate the functional results of Type 2 distal endclavicle fractures treated with superior anterior l...
متن کاملA Pitfall in Fixation of Distal Humeral Fractures with Pre-Contoured Locking Compression Plate
Anatomically precontoured locking plates are intended to facilitate the fixation of articular fractures and particularly those associated with osteoporosis. Fractures of the distal humerus are relatively uncommon injuries where operative intervention can be exceptionally challenging. The distal humeral trochlea provides a very narrow anatomical window through which to pass a fixed-angle locking...
متن کاملFunctional outcome of distal femoral fractures treated by minimally invasive surgery using locking condylar plate
Correspondence should be sent to: [email protected] ABSTRACT Background: The management of distal femoral fractures has presented significant challenge to Orthopaedic surgeons. A wide medullary canal, thin cortex and poor bone stock make stable internal fixation in these fractures difficult. Severe soft tissue damage, extensive comminution, intrarticular extension and injury to quadriceps mecha...
متن کاملsurgical treatment of unstable distal radius fractures with a volar variable-angle locking plate: clinical and radiological outcomes
conclusions the use of variable-angle locking plates in treating unstable distal end radius fractures is associated with excellent to good functional outcomes with minimal complications. objectives this study aimed to evaluate the functional and radiological outcomes in unstable distal end radius fractures treated with variable-angle locking plates. patients and methods we reviewed 23 unstable ...
متن کاملLocking versus nonlocking palmar plate fixation of distal radius fractures.
This study compared functional and radiological outcomes after treatment of extension-type distal radius fractures with conventional titanium nonlocking T-plates or titanium 1.5-mm locking plates. A total of 60 patients were included and followed for 4 to 7 years after receiving nonlocking T-plates (group A; n=30) or locking plates (group B; n=30) with and without dorsal bone grafting. Bone gra...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Research in Medical Sciences
سال: 2017
ISSN: 2320-6012,2320-6071