Geometric Parameters Estimation and Calibration in Cone-Beam Micro-CT
نویسندگان
چکیده
منابع مشابه
Geometric Parameters Estimation and Calibration in Cone-Beam Micro-CT
The quality of Computed Tomography (CT) images crucially depends on the precise knowledge of the scanner geometry. Therefore, it is necessary to estimate and calibrate the misalignments before image acquisition. In this paper, a Two-Piece-Ball (TPB) phantom is used to estimate a set of parameters that describe the geometry of a cone-beam CT system. Only multiple projections of the TPB phantom a...
متن کاملAuto calibration of a cone-beam-CT.
PURPOSE This paper introduces a novel autocalibration method for cone-beam-CTs (CBCT) or flat-panel CTs, assuming a perfect rotation. The method is based on ellipse-fitting. Autocalibration refers to accurate recovery of the geometric alignment of a CBCT device from projection images alone, without any manual measurements. METHODS The authors use test objects containing small arbitrarily posi...
متن کاملSelf-calibration of geometric and radiometric parameters for cone-beam computed tomography
Thanks to the advances in parallel processing hardware, iterative algorithms for cone beam reconstruction are now available with computation times acceptable for clinical use. At the same time they are able to accomodate more accurately the physical effects underlying the X-Ray imaging process. Many parameters are involved, which need to be precisely calibrated in order to achieve an accurate 3...
متن کاملGeometric calibration of a mobile C-arm for intraoperative cone-beam CT.
A geometric calibration method that determines a complete description of source-detector geometry was adapted to a mobile C-arm for cone-beam computed tomography (CBCT). The non-iterative calibration algorithm calculates a unique solution for the positions of the source (X(s), Y(s), Z(s)), detector (X(d), Y(d), Z(d)), piercing point (U(o), V(o)), and detector rotation angles (phi, theta, eta) b...
متن کاملIterative reconstruction optimisations for high angle cone-beam micro-CT
We address several acquisition questions that have arisen for the high cone-angle helical-scanning micro-CT facility developed at the Australian National University. These challenges are generally known in medical and industrial cone-beam scanners but can be neglected in these systems. For our large datasets, with more than 2048 voxels, minimising the number of operations (or iterations) is cru...