Graphene Modified Electrode for the Direct Electron Transfer of Bilirubin Oxidase
نویسندگان
چکیده
منابع مشابه
Direct heterogeneous electron transfer of theophylline oxidase.
Direct electron transfer (DET) was shown between the heme containing enzyme theophylline oxidase (ThO) and the surface of both graphite and gold electrodes. As proof on graphite a steady state current for theophylline was recorded using the electrode modified with adsorbed ThO. The electrode showed a Michaelis-Menten-like response to theophylline with a detection limit of 0.2 mM and a Michaelis...
متن کاملReagentless glucose biosensor based on direct electron transfer of glucose oxidase immobilized on colloidal gold modified carbon paste electrode.
The direct electrochemistry of glucose oxidase (GOD) adsorbed on a colloidal gold modified carbon paste electrode was investigated. The adsorbed GOD displayed a pair of redox peaks with a formal potential of -(449+/-1) mV in 0.1 M pH 5.0 phosphate buffer solution. The response showed a surface-controlled electrode process with an electron transfer rate constant of (38.9+/-5.3)/s determined in t...
متن کاملDirect Electron Transfer of Hemoglobin on Manganese III Oxide-Ag Nanofibers Modified Glassy Carbon Electrode
We investigated the electrochemical behavior of hemoglobin by glassy carbon electrode modified with Mn(2)O(3)-Ag nanofibers. The Mn(2)O(3)-Ag nanofibers were used as facilitator electron transfer between Hb and glassy-carbon-modified electrode. The Mn(2)O(3)-Ag nanofibers are studied by scanning electron microscopy (SEM) and transmission electron microscopy (TEM). The hemoglobin showed a quasir...
متن کاملMeasurement of direct bilirubin by use of bilirubin oxidase.
We developed an enzymatic method for measuring direct-reacting bilirubin (DBIL) in serum. At pH 4.5, bilirubin oxidase (BOX) oxidizes mono-conjugated bilirubin, di-conjugated bilirubin, and most of the delta-bilirubin to biliverdin. The resulting decrease in absorbance at 460 nm is linearly related to the concentration of DBIL in serum. Mean DBIL values in the 51 patients' sera examined by the ...
متن کاملZnO-nanorods/graphene heterostructure: a direct electron transfer glucose biosensor
ZnO-nanorods/graphene heterostructure was synthesized by hydrothermal growth of ZnO nanorods on chemically reduced graphene (CRG) film. The hybrid structure was demonstrated as a biosensor, where direct electron transfer between glucose oxidase (GOD) and electrode was observed. The charge transfer was attributed to the ZnO nanorod wiring between the redox center of GOD and electrode, and the Zn...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Electrochemistry
سال: 2015
ISSN: 1344-3542,2186-2451