Heat Transfer of a Single-Phase Natural Circulation Loop With Heating and Cooling Fluids
نویسندگان
چکیده
منابع مشابه
Experimental Investigation of Heat Transfer Enhancement in a Finned U-Shaped Heat Pipe of CPU Cooling System Using Different Fluids
This paper experimentally studies the heat absorption performance of a heat sink with vertical embedded heat pipes in the aluminum blade. The cooling system with embedded heat pipes distributes heat from the CPU to both the base plate and the heat pipes, and then transfer heat from fins to the Environment. The thermal resistance and heat transfer coefficient are evaluated for natural convection...
متن کاملA NUMERICAL STUDY OF SINGLE-PHASE FORCED CONVECTIVE HEAT TRANSFER WITH FLOW FRICTION IN MICROCHANNELS (RESEARCH NOTE)
Three-dimensional simulations of the single-phase laminar flow and forced convective heat transfer of water in microchannels with small rectangular sections having specific hydraulic diameters and distinct geometric configurations were investigated numerically. The numerical results indicated that the laminar heat transfer was to be dependent upon the aspect ratio and the ratio of the hydraulic...
متن کاملExperimental Heat Transfer Enhancement in Single-phase Liquid Microchannel Cooling with Cross-flow Synthetic Jet
The present study experimentally investigated a new hybrid cooling scheme by combination of a microchannel heat sink with a micro-synthetic jet actuator. The heat sink consisted of a single rectangular microchannel measured 550 μm wide, 500 μm deep and 26 mm long. The synthetic jet actuator with a 100 μm diameter orifice was placed right above the microchannel and 5 mm downstream from the chann...
متن کاملSingle ! phase heat transfer enhancement in a curved \ rectangular channel subjected to concave heating
Experiments were performed to ascertain the single!phase heat transfer enhancement provided by streamwise curva! ture[ Curved and straight rectangular ~ow channels were fabricated with identical 4[9×1[4 mm cross!sections and 090[5 mm heated lengths in which heat was applied to a 21[2 mm radius concave wall in the curved channel and a side wall in the straight[ Reynolds number ranged from 8999 t...
متن کاملSingle-phase Coolant Flow and Heat Transfer
1) Hydraulic Analysis of the Emergency Core Spray System in a BWR The emergency spray system of a BWR delivers cold water to the core after a large-break loss of coolant accident has emptied the reactor vessel. The system comprises a large water pool, a pump, a spray nozzle and connecting pipes (Figure 1). All pipes are smooth round tubes made of stainless steel with 10 cm internal diameter. Th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Energy Procedia
سال: 2017
ISSN: 1876-6102
DOI: 10.1016/j.egypro.2017.12.298