Horizontal earth-air heat exchanger for preheating external air in the mechanical ventilation system
نویسندگان
چکیده
منابع مشابه
Heat transfer enhancement due to air bubble injection into a horizontal double pipe heat exchanger
If an air flow is injected into a liquid fluid, many ambulant air bubbles are formed inside the fluid. Air bubbles move inside the liquid fluid because of the buoyancy force, and the mobility of these air bubbles makes sizable commixture and turbulence inside the fluid. This mechanism was employed to enhance the heat transfer rate of a horizontal double pipe heat exchanger in this paper. Howeve...
متن کاملPassive Energy Air-to-Water Heat Pipe Based Heat Exchanger and its Potential of Air Pre-cooling in Air Conditioning Systems for Iran Climate
Air pre-cooling equipment is normally being employed in air-conditioning systems for pre-cooling the ambient outdoor air to enhance the air-conditioning systems performance. In this study, the potential of a passive water-to-air heat pipe based heat exchanger (HPHEX) for air pre-cooling purpose in air-conditioning systems for the high cooling load demanding regions of Iran was investigated. To ...
متن کاملheat transfer enhancement due to air bubble injection into a horizontal double pipe heat exchanger
if an air flow is injected into a liquid fluid, many ambulant air bubbles are formed inside the fluid. air bubbles move inside the liquid fluid because of the buoyancy force, and the mobility of these air bubbles makes sizable commixture and turbulence inside the fluid. this mechanism was employed to enhance the heat transfer rate of a horizontal double pipe heat exchanger in this paper. howeve...
متن کاملDesign of an Earth Air Heat Exchanger (EAHE) for Climatic Condition of Chennai, India
In the present work the ground temperature has been validated for climatic condition of Sriperumbudur near Chennai, India to evaluate thermal conductivity and diffusivity of the soil. For the evaluated thermal conductivity of the soil, an EAHE has been designed for a given dimension of room with optimized values of number of air changes, length of pipe, radius of pipe and depth at which heat ex...
متن کاملA Literature Review On Heat Exchanger Air Side Fouling In Heating, Ventilation And Air-conditioning (HVAC) Applications
This paper provides a review on the fouling mechanism and its effect onto the performance of finned tube heat exchangers in HVAC systems. Fouling tends to degrade the performance of heat exchangers by decreasing the heat transfer coefficient and increasing the air-side pressure drop across the heat exchangers. Air side fouling depends on a number of factors on the air side, including type and c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Selected Scientific Papers - Journal of Civil Engineering
سال: 2018
ISSN: 1338-7278
DOI: 10.1515/sspjce-2018-0021