HVDC System Commutation Failure Transient Judgement Method
نویسندگان
چکیده
منابع مشابه
Mitigation of commutation faults in HVDC system
To transfer large amount of direct current power having high amplitude voltage over long distance, high voltage direct current (HVDC) transmission system is used. This system was introduced 60 year ago and now it is widely used all over the world. Some examples of HVDC systems are following; Voltage-SourcedConverter (VSC), current commutated converter (CCC) and line commutated converter (LCC) d...
متن کاملDecreasing the Commutation Failure Frequency in HVDC Transmission Systems
In this paper we show how a fairly large proportion of those commutation failures that are due to single-phased short circuits to earth can be avoided. In a control circuit based on a digital signal processor (DSP) it is possible, with instantaneous results, to switch from a normal control strategy with equidistant firing pulses to a strategy that takes into consideration the potentially danger...
متن کاملOn the Double Commutation Method
We provide a complete spectral characterization of the double commutation method for general Sturm-Liouville operators which inserts any finite number of prescribed eigenvalues into spectral gaps of a given background operator. Moreover, we explicitly determine the transformation operator which links the background operator to its doubly commuted version (resulting in extensions and considerabl...
متن کاملNovel transient-energy-based directional pilot protection method for HVDC line
This paper proposes a novel directional pilot protection method based on the transient energy for bipolar HVDC line. Supposing the positive direction of current is from DC bus to the DC line, in the case of an internal line fault, the transient energies detected on both sides of the line are all negative within a short time, which denotes the positive direction fault; while for an external faul...
متن کاملTransient-free commutation of a resonant-mode array of inductors
A method and system are proposed for a transient-free commutation of a resonant-mode array of inductors. A single capacitor is used to tune the entire array, and triacs are used to commutate the inductors. To avoid the transients, the tuning capacitor is electrically locked when it stores the whole energy of the excited circuit. This prevents the capacitor from discharge during the fast, 0.1 ms...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: DEStech Transactions on Engineering and Technology Research
سال: 2019
ISSN: 2475-885X
DOI: 10.12783/dtetr/aemce2019/29485