Hydroxide Ion-Selective Polymeric Membrane-Coated Wire Electrode Based on Oxomolybdenum(V) Tetraphenylporphyrin Complex

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Coated-wire iron(III) ion-selective electrode based on iron complex of 1,4,8,11-tetraazacyclotetradecane

The work described here comprises the determination of Fe(III) by ion selective potentiometry using a coated-wire ion-selective electrode (CWISE) based on iron–cyclam complex. Linear Nernstian response for this electrode was obtained over the total Fe(III) concentration range of 1× 10−2 to 1× 10−6 M in 0.05 M HNO3, H2SO4, HClO4, HCl, KNO3 and KCl media, with a slope of 60± 5 mV per decade chang...

متن کامل

Coated-wire silver ion-selective electrode based on silver complex of cyclam.

A coated-wire ion-selective electrode (ISE) based on cyclam (1,4,8,11-tetraazacyclotetradecane) as a neutral carrier in a polyvinyl chloride (PVC) matrix was fabricated for the determination of Ag(I) ions. The coated-wire ISE exhibited a linear Nernstian response over the range 1 x 10(-1) to 1 x 10(-7) M with a slope of 59 +/- 2 mV per decade change and a detection limit of 5 x 10(-8) M. The IS...

متن کامل

Selective Membrane Electrode for Bromide Ion Based on Aza Pyrilium Ion Derivative as a new Ionophore.

A highly selective electrode for Bromide ion based on aza pyrilium derivative as an excellentionophore is described.The sensor exhibits a good linear response with a slope of ( 60±1 ) mV per decadeover the concentration range of ( 1×10-3 – 9×10-6 M ) , and a detection limit of ( 3×10-6 M ) of Bromideions .The electrode response is independent of pH in the range of(4.0 –9.5).Selectivity coeffici...

متن کامل

Coated wire silver-ion selective electrode based on a N,N'-bis(2-thienylmethylene)-1,2-diaminobenzene.

A novel membrane coated platinum-wire electrode (MCPWE) based on N,N'-bis(2-thienylmethylene)-1,2-diaminobenzene (BTMD) for highly selective determination of Ag+ ion has been developed. The influences of membrane composition and pH on the potentiometric responses of electrode were investigated. The potentiometric responses are independent of the pH of the test solution in the range of 5.0 - 9.0...

متن کامل

Cu(II) Ion- Selective Membrane Electrode Based on bis(N-salicylidene-3,3'-diamino diphenyl) sulfone

In order to study the Cu(II) ion selective electrode, an optimized membrane was prepared by mixing of 30 mg of PVC powdered, 5 mg of considered ionophore, 60 mg of plasticizer and 5 mg of additive. The sensor showed a near Nernstian response for Cu(II) ions over a concentration range from 1.0×0-6 –1.0×0-2 M with a slope of 28.90.5 mV per concentration decade with a working pH range of 3.5-6.3. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Bulletin of the Chemical Society of Japan

سال: 1990

ISSN: 0009-2673,1348-0634

DOI: 10.1246/bcsj.63.1360