Improving Heart Rate Estimation on Consumer Grade Wrist-Worn Device Using Post-Calibration Approach

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy of a Wrist-Worn Heart Rate Sensing Device during Elective Pediatric Surgical Procedures

The reliability of wearable photoplethysmography (PPG) sensors to measure heart rate (HR) in hospitalized patients has only been demonstrated in adults. We evaluated the accuracy of HR monitoring with a personal fitness tracker (PFT) in children undergoing surgery. HR monitoring was performed using a wrist-worn PFT (Fitbit Charge HR) in 30 children (8.21 ± 3.09 years) undergoing laparoscopy (n ...

متن کامل

Real-Time Monitoring in Home-Based Cardiac Rehabilitation Using Wrist-Worn Heart Rate Devices

Cardiac rehabilitation is a key program which significantly reduces the mortality in at-risk patients with ischemic heart disease; however, there is a lack of accessibility to these programs in health centers. To resolve this issue, home-based programs for cardiac rehabilitation have arisen as a potential solution. In this work, we present an approach based on a new generation of wrist-worn dev...

متن کامل

Portable Wrist Located Heart Rate Moni- Toring Device

Portable heart rate monitoring devices are classically composed of a processing device and an external probe (e.g. electronic stethoscope, optical measure at ear lobe, chest belt for ECG based measurement, etc.). The use of an external probe is often considered as a reduction of the comfort. We propose a new fully integrated measurement system that is located at the wrist. This system is based ...

متن کامل

A Wrist-Worn Thermohaptic Device for Graceful Interruption

Thermal haptics is a potential system output modality for wearable devices that promises to function at the periphery of human attention. When adequately combined with existing attention-governing mechanisms of the human mind, it could be used for interrupting the human agent at a time when the negative influence on the ongoing activity is minimal. In this article we present our self-mitigated ...

متن کامل

Robust heart rate estimation using wrist-type photoplethysmographic signals during physical exercise: an approach based on adaptive filtering.

Photoplethysmographic (PPG) signals are easily corrupted by motion artifacts when the subjects perform physical exercise. This paper introduces a two-step processing scheme to estimate heart rate (HR) from wrist-type PPG signals strongly corrupted by motion artifacts. Adaptive noise cancellation, using normalized least-mean-square algorithm, is first performed to attenuate motion artifacts and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEEE Sensors Journal

سال: 2020

ISSN: 1530-437X,1558-1748,2379-9153

DOI: 10.1109/jsen.2020.2979191