Dynamic intensity modulated radiation therapy (IMRT) to treat prostate and pelvic nodes using the Varian 120-leaf Millennium multileaf collimator (MLC) has been implemented in our clinic. This paper describes the procedures that have been undertaken to achieve this, including some of the commissioning aspects of Helios, verification of the dynamic dose delivery, and quality assurance (QA) of th...
متن کاملOptimal Multileaf Collimator Leaf Sequencing in IMRT Treatment Planning
We consider a problem dealing with the efficient delivery of Intensity Modulated Radiation Therapy (IMRT) to individual patients. IMRT treatment planning is usually performed in three phases. The first phase determines a set of beam angles through which radiation is delivered, followed by a second phase that determines an optimal radiation intensity profile (or fluence map). This intensity prof...
متن کاملStereotactic IMRT for prostate cancer: Dosimetric impact of multileaf collimator leaf width in the treatment of prostate cancer with IMRT
The focus of this work is the dosimetric impact of multileaf collimator (MLC) leaf width on the treatment of prostate cancer with intensity-modulated radiation therapy (IMRT). Ten patients with prostate cancer were planned for IMRT delivery using two different MLC leaf widths--4mm and 10mm--representing the Radionics micro-multileaf collimator (mMLC) and Siemens MLC, respectively. Treatment pla...
متن کاملIncorporating multi-leaf collimator leaf sequencing into iterative IMRT optimization.
Intensity modulated radiation therapy (IMRT) treatment planning typically considers beam optimization and beam delivery as separate tasks. Following optimization, a multi-leaf collimator (MLC) or other beam delivery device is used to generate fluence patterns for patient treatment delivery. Due to limitations and characteristics of the MLC, the deliverable intensity distributions often differ f...
متن کاملPhysical and dosimetric characteristic of high‐definition multileaf collimator (HDMLC) for SRS and IMRT
Physical and dosimetric characteristics of HDMLC were studied for SRS6, 6, and 10 MV X-rays from Novalis Tx. This in-built tertiary collimator consists of 60 pairs (32 × 0.25 cm; 26 × 0.5 cm and 2 × 0.7 cm) of leaves. Properties of HDMLC studied included alignment, readout and radiation field congruence, radiation penumbra, accuracy and reproducibility of leaf position and gap width, static and...