Interpolation based Low Dose CT Image Reconstruction

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Gamma regularization based reconstruction for low dose CT.

Reducing the radiation in computerized tomography is today a major concern in radiology. Low dose computerized tomography (LDCT) offers a sound way to deal with this problem. However, more severe noise in the reconstructed CT images is observed under low dose scan protocols (e.g. lowered tube current or voltage values). In this paper we propose a Gamma regularization based algorithm for LDCT im...

متن کامل

Ultra-Low Dose CT Image Reconstruction Based on Big Data Priors

1 Executive summary This project will develop a dramatically improved approach to low-dose X-ray CT image formation by extracting and using information from a big-data corpus of regular dose CT images. X-Ray Computed Tomography (CT) provides high-resolution images of anatomical structures for diagnosis and management of human diseases and disorders. For example, CT has had a tremendous impact o...

متن کامل

Variational Bayesian blind restoration reconstruction based on shear wave transform for low-dose medical CT image

A variational Bayesian blind restoration reconstruction based on shear wave transform for low-dose medical computed tomography (CT) image is proposed. The proposed algorithm eliminates the effects of the point spread function in the process of low-dose medical CT image reconstruction and improves the reconstructed image quality. The shear wave transform is used to sparsely represent the CT imag...

متن کامل

Database-assisted low-dose CT image restoration.

PURPOSE Acquiring data for CT at low radiation doses has become a pressing goal. Unfortunately, the reduced data quality adversely affects the quality of the reconstructions, impeding their readability. In previous work, the authors showed how a prior regular-dose scan of the same patient can efficiently be used to mitigate low-dose artifacts. However, since a prior is not always available, the...

متن کامل

Low-dose spectral CT reconstruction using L0 image gradient and tensor dictionary

Weiwen Wu1,2, Yanbo Zhang2, Qian Wang2, Fenglin Liu1,3,*, Peijun Chen1 and Hengyong Yu2,* 1Key Lab of Optoelectronic Technology and Systems, Ministry of Education, Chongqing University, Chongqing 400044, China 2Department of Electrical and Computer Engineering, University of Massachusetts Lowell, Lowell, MA 01854, USA 3Engineering Research Center of Industrial Computed Tomography Nondestructive...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Procedia Computer Science

سال: 2020

ISSN: 1877-0509

DOI: 10.1016/j.procs.2020.04.300