Intraocular lens power calculation using ray tracing following excimer laser surgery
نویسندگان
چکیده
منابع مشابه
Intraocular lens power calculation following laser refractive surgery
Refractive outcomes following cataract surgery in patients that have previously undergone laser refractive surgery have traditionally been underwhelming. This is related to several key issues including the preoperative assessment (keratometry) and intraocular lens power calculations. Peer-reviewed literature is overwhelmed by the influx of methodology to manipulate the corneal or intraocular le...
متن کاملintraocular lens power calculation after keratorefractive surgery
purpose: to determine corneal power for intraocular lens (iol) power calculation in eyes with previous keratorefractive surgery. methods: in 13 eyes of 9 patients with previous keratorefractive surgery undergoing phacoemulcification, iol power was calculated using the clinical history method (chm) in one case, manual keratometry (mkr) in 2, simk in 3, and flattest k (topographically derived) in...
متن کاملIntraocular lens power calculation for cataract surgery after photorefractive keratectomy.
OBJECTIVE To assess intraocular lens (IOL) power calculations in patients undergoing cataract surgery after excimer laser photorefractive keratectomy (PRK) for myopia. METHODS Four eyes of two patients underwent phacoemulsification with IOL implantation after PRK for myopia. The estimated refractive error that would have been induced had the IOL predicted for emmetropia been implanted was cal...
متن کامل[Trial of new intraocular lens power calculation following phototherapeutic keratectomy].
We reviewed the SRK-II method and introduce a new equation to calculate the intraocular lens (IOL) power for eyes which underwent laser phototherapeutic keratectomy (PTK). The Gullstrand series was used to determine the power and the radius of curvature of planoconvex IOLs which alter the focal point from the cornea to reach the conjugate point on the retina. The radius of anterior corneal curv...
متن کاملAccuracy of intraocular lens power calculation in paediatric cataract surgery.
AIMS To determine the accuracy of intraocular lens (IOL) power calculation in a group of pseudophakic children. METHODS A retrospective analysis of biometric and refractive data was performed on 52 eyes of 40 infants and children, who successfully underwent cataract extraction and IOL implantation. The following parameters were included: age at the time of surgery, keratometry, axial length, ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Eye
سال: 2006
ISSN: 0950-222X,1476-5454
DOI: 10.1038/sj.eye.6702300