Investigation of natural frequencies of axially loaded thin-walled columns
نویسندگان
چکیده
منابع مشابه
Euler Buckling of Thin - Walled Composite Columns •
Pultruded composite structural members with open or closed thin-walled sections are being extensively used as columns for structural applications l1Jhere buckling is the main consideration in the design. In this paper, global buckling is investigated and critical loads are experimentally determined for various fiber reinforced composite I-beams of long column length. Southwell's method is used ...
متن کاملImperfection-Insensitive Axially Loaded Thin Cylindrical Shells
The high efficiency of circular monocoque cylindrical shells in carrying axial loads is impaired by their extreme sensitivity to imperfections and there is an extensive body of literature that addresses this behavior. Instead of following this classical path, focused on circular cross-sections, this paper presents a novel approach that adopts optimal symmetry-breaking wavy cross-sections (wavy ...
متن کاملLocal, Distortional, and Euler Buckling of Thin-Walled Columns
Open cross-section, thin-walled, cold-formed steel columns have at least three competing buckling modes: local, distortional, and Euler ~i.e., flexural or flexural-torsional! buckling. Closed-form prediction of the buckling stress in the local mode, including interaction of the connected elements, and the distortional mode, including consideration of the elastic and geometric stiffness at the w...
متن کاملStatic and dynamic axial crushing of prismatic thin-walled metal columns
In this paper, a novel approach is proposed to investigate the progressive collapse damage of prismatic thin walled metal columns with different regular cross sections, under the action of axial quasi-static and impact loads. The present work mainly focuses on implementation of some important factors which have been neglected in other studies. These factors include the effect of reducing impact...
متن کاملFire behavior of axially loaded slender high strength concrete - filled tubular columns
This paper describes sixteen fire tests conducted on slender circular hollow section columns filled with normal and high strength concrete, subjected to concentric axial loads. The test parameters were the nominal strength of concrete (30 and 80 MPa), the infilling type (plain concrete, reinforced concrete and steel fiber reinforced concrete) and the axial load level (20% and 40%). The columns ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: MATEC Web of Conferences
سال: 2018
ISSN: 2261-236X
DOI: 10.1051/matecconf/201821902018