K wire: a lethal implant

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A simple K-wire cap.

The authors describe a simple technique to cap sticking K-wires using plastic syringes readily available in the hospitals, that has not been described before.

متن کامل

K-Wire Breakage During Metalware Removal Due to a Defective K-Wire Shaft

1. McIndoe A. The treatment of congenital absence and obliterative conditions of the vagina. Br J Plast Surg 1950;2:254-67. 2. Concannon MJ, Croll GH, Puckett CL. An intraoperative stent for McIndoe vaginal construction. Plast Reconstr Surg 1993;91:367-8. 3. Chen TH. Refinement of McIndoe's vaginal reconstruction with ORFIT "S" vaginal stent. Plast Reconstr Surg 1994; 94:394-6. 4. Sabino Neto M...

متن کامل

distraction osteogenesis in the hand with and without k-wire

normal 0 false false false en-us x-none ar-sa microsoftinternetexplorer4 background : distraction osteogenesis is an established option for reconstruction of amputated fingers. in contrast to the primary method of distraction osteogenesis, using kirschner wire (k-wire) as an internal fixator is not common today. this study was conducted to evaluate distraction osteogenesis with and without k-wi...

متن کامل

Wire-bonding process development for low-k materials

A 60-lm bond-pad-pitch wire-bonding process was developed using test dies with a SiO2 dielectric layer under aluminium pads, and was then fine-tuned for a low-k device using three types of gold wires with different mechanical properties. Bulk material hardness of the wires were characterised using a wire-bonding machine, the force applied and diameters of squashed free-air balls. It was found t...

متن کامل

Percutaneous K-wire buttress technique for displaced radial neck fracture.

Radial neck fractures are uncommon injuries in adults and more often found in children, where they account for 5-8.5% of elbow injuries. It is generally agreed that an angulation of less than 30 degrees is acceptable. However, anything greater than this should be improved in an attempt to restore normal anatomy and maximize the range of movement. We describe our management of a radial neck frac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: International Journal of Scientific Reports

سال: 2015

ISSN: 2454-2164,2454-2156

DOI: 10.18203/issn.2454-2156.intjscirep20150208