Log-Normal ELISPOT spot size distribution permits count harmonization among different laboratories

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Log-Normal ELISPOT spot size distribution permits count harmonization among different laboratories

Introduction ELISPOT assays are primarily used to detect the number of T cells that respond to a given antigen. With that number being absolute for any given donor sample, ELISPOT counts should be similar between laboratories, if subjectivity in counting is avoided. Due to the differences in spot sizes ranging from microns to millimeters, setting cut offs for minimal and maximal spot sizes will...

متن کامل

Gradually Truncated Log-normal distribution - Size distribution of firms

Many natural and economical phenomena are described through power law or log-normal distributions. In these cases, probability decreases very slowly with step size compared to normal distribution. Thus it is essential to cut-off these distributions for larger step size. Recently we introduce the gradually truncated power law distribution to successfully describe variation of financial, educatio...

متن کامل

ELISPOT assays provide reproducible results among different laboratories for T-cell immune monitoring--even in hands of ELISPOT-inexperienced investigators.

Measurements of antibodies in bodily fluids (e.g., by ELISA) have provided robust and reproducible results for decades and such assays have been validated for monitoring of B-cell immunity. In contrast, measuring T-cell immunity has proven to be a challenge due to the need to test live cells in functional assays ex vivo. Several previous efforts looking into the reproducibility of ex vivo T-cel...

متن کامل

High Reproducibility of ELISPOT Counts from Nine Different Laboratories

The primary goal of immune monitoring with ELISPOT is to measure the number of T cells, specific for any antigen, accurately and reproducibly between different laboratories. In ELISPOT assays, antigen-specific T cells secrete cytokines, forming spots of different sizes on a membrane with variable background intensities. Due to the subjective nature of judging maximal and minimal spot sizes, dif...

متن کامل

comparing log-normal and gamma distribution models for representation of soil particle-size distribution

abstract in recent years, many researchers have attempted to estimate the soil hydraulic functions (e.g. soil moisture characteristics curve, and hydraulic conductivity function) using particle-size distribution (psd) curve. in these studies, an accurate mathematical representation of psd is required for fitting the observed data. so far, some mathematical models were developed with different l...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal for ImmunoTherapy of Cancer

سال: 2014

ISSN: 2051-1426

DOI: 10.1186/2051-1426-2-s3-p156