Loss of guidewire
نویسندگان
چکیده
منابع مشابه
Knuckle wire and stingray balloon for recrossing a coronary dissection after loss of guidewire position.
Coronary angiography demonstrating a tortuous right coronary ar Mid right coronary artery dissection after balloon pre-dilation (arro unsuccessful attempt for stent delivery. After failure to advance a a Pilot 200 guidewire (Abbott Vascular, Santa Clara, California) (arr balloon (Bridgepoint Medical, Minneapolis, Minnesota) (arrows, D) Guideliner catheter (Vascular Solutions, Minneapolis, Minne...
متن کاملPreventing the guidewire escape.
To the Editor: We read with interest the article by Gulel et al. who presented a case of a missed guidewire complicated by pulmonary and systemic embolism from thrombi that formed on the wire surface. We have previously reported on missing the guidewire during central venous catheterization and described several precautions and technical modifications to prevent the guidewire escape. We believe...
متن کاملSafety and Functionality of a Guidewire Fixator
OBJECTIVE A new endovascular tool, the Liungman Guidewire Fixator, has been developed to simplify endovascular treatment in complex aortic aneurysms. The device has been extensively tested in bench models and animal trials. To verify the safety and functionality demonstrated in the porcine model, the device was tested in ten patients undergoing endovascular aortic repair (EVAR) or fenestrated e...
متن کاملConservative management of broken guidewire: Case reports
Fractures of coronary guidewires during percutaneous coronary intervention within a coronary vessel lumen are a rare but serious complication. There have been several cases reported in the literature, some managed with surgical intervention, others with medical therapy. We present two prospective cases from our center. Both cases were managed successfully with medical therapy.
متن کاملEffect of guidewire on contribution of loss due to momentum change and viscous loss to the translesional pressure drop across coronary artery stenosis: An analytical approach
BACKGROUND Guidewire (GW) size and stenosis dimensions are the two major factors affecting the translesional pressure drop. Studying the combined effect of these parameters on the mean pressure drop (Δp) across the stenosis is of high practical importance. METHODS In this study, time averaged mass and momentum conservation equations are solved analytically to obtain pressure drop-flow, Δp-Q, ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Indian Journal of Critical Care Medicine
سال: 2018
ISSN: 0972-5229,1998-359X
DOI: 10.4103/ijccm.ijccm_93_18