MALDI In-Source Decay of Protein

نویسندگان

چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In-Source Decay and Pseudo-MS3 of Peptide and Protein Ions Using Liquid AP-MALDI

Atmospheric pressure MALDI on a Q-Exactive instrument was optimized for in-source decay and pseudo-MS3. The dependence of AP-MALDI ISD on the MALDI liquid matrix was investigated for peptides and proteins. The liquid matrices enabled long-life ISD signal, and exhibited high fragment ion yield and signal stability. Extensive a-, b-, c-, y-, and z-type fragment series were observed depending on t...

متن کامل

MALDI in-source decay, from sequencing to imaging.

Matrix-assisted laser desorption/ionization (MALDI) is now a mature method allowing the identification and, more challenging, the quantification of biopolymers (proteins, nucleic acids, glycans, etc). MALDI spectra show mostly intact singly charged ions. To obtain fragments, the activation of singly charged precursors is necessary, but not efficient above 3.5 kDa, thus making MALDI MS/MS diffic...

متن کامل

Fragmentation of peptides in MALDI in-source decay mediated by hydrogen radicals.

In-source decay (ISD) in matrix-assisted laser desorption/ionization (MALDI) shares some similarities with the novel fragmentation technique electron capture dissociation (ECD). In both reactions, the otherwise strong N-C(alpha) bond is cleaved, forming fragment ions of the c and z types, while labile posttranslational modifications are preserved. Therefore, it is tempting to assume that ISD an...

متن کامل

Top-Down Sequencing of Intact Proteins by MALDI In Source Decay (ISD)

Although MALDI mass spectrometry is a soft ionization technique which enables desorption of high molecular weight biomolecules exceeding several hundred kDa, it became apparent that some analyte fragmentation occurs during the MALDI process as well. The processes of fragmentation initially characterized on MALDI-TOF mass spectrometers were designated as either; (i) in-source decay (ISD), the co...

متن کامل

Characterization of a novel Sepia officinalis neuropeptide using MALDI-TOF MS and post-source decay analysis.

A novel neuropeptide acting as a myosuppressor on esophagus, funnel and mantle muscular fibers has been isolated from the stellar ganglia of the mollusk cephalopod Sepia officinalis by means of HPLC analysis. Fractions were monitored using a myotropic bioassay. After three separation steps, MALDI-TOF spectrum revealed one main peak at m/z 756.6. The partial N-terminal and C-terminal digestions ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Mass Spectrometry

سال: 2016

ISSN: 2186-5116,2187-137X

DOI: 10.5702/massspectrometry.a0044